Influence of thread profiles, microthreads, and cutting flutes on dental implant performance: A finite element study

Dental implant success is highly dependent on implant design parameters such as thread profile, micro-threading, and cutting flutes, bone quality and loading conditions. Enhancing these design parameters is essential to achieve better stress dispersion and ensure stability at the implant bone junction, especially in regions with differing bone densities. This research aims to understand the influence of thread profiles, micro-threading conditions, and cutting flutes using finite element analysis. A total of 24 implant models were designed, incorporating variations in thread geometry and flute configurations, as well as the presence or absence of micro threads. The research focuses on stress distribution in cortical and cancellous bone under a standardized 100 N load at 45° across Type IV bone density. Maximum von Mises stress in cortical bone was observed in the buttress profile with micro-threads and 2 cutting flutes, whereas the non-micro-threaded square profile with 4 cutting flutes exhibited the highest stress in cancellous bone (17.14 MPa). Introducing coronal micro-threads increased peak cortical bone stress by 15%-20% on average while shielding the underlying cancellous bone. Increasing cutting flutes from 2 to 4 contributed to stress reduction primarily in micro-threaded configurations, whereas its effect in non-micro-threaded models was minimal. Within the parameters evaluated, implant design modifications altered simulated stress distribution across cortical and cancellous bone regions in low-density bone. Because specific configurations reduced cancellous stress while increasing peak cortical stress, design selection involves balancing localized cortical stress concentration with stress transmission into the underlying cancellous bone.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Published
2026-11-25
DOI
https://doi.org/10.1177/09544119261508972
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Influence of thread profiles, microthreads, and cutting flutes on dental implant performance: A finite element study

Pankaj N. Dhatrak, Santosh Patil, Ayush Yadav
1 links
Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
Dental Implant Techniques and Outcomes
article

Influence of thread profiles, microthreads, and cutting flutes on dental implant performance: A finite element study

Pankaj N. Dhatrak, Santosh Patil, Ayush Yadav
article en

Abstract

Dental implant success is highly dependent on implant design parameters such as thread profile, micro-threading, and cutting flutes, bone quality and loading conditions. Enhancing these design parameters is essential to achieve better stress dispersion and ensure stability at the implant bone junction, especially in regions with differing bone densities. This research aims to understand the influence of thread profiles, micro-threading conditions, and cutting flutes using finite element analysis. A total of 24 implant models were designed, incorporating variations in thread geometry and flute configurations, as well as the presence or absence of micro threads. The research focuses on stress distribution in cortical and cancellous bone under a standardized 100 N load at 45° across Type IV bone density. Maximum von Mises stress in cortical bone was observed in the buttress profile with micro-threads and 2 cutting flutes, whereas the non-micro-threaded square profile with 4 cutting flutes exhibited the highest stress in cancellous bone (17.14 MPa). Introducing coronal micro-threads increased peak cortical bone stress by 15%-20% on average while shielding the underlying cancellous bone. Increasing cutting flutes from 2 to 4 contributed to stress reduction primarily in micro-threaded configurations, whereas its effect in non-micro-threaded models was minimal. Within the parameters evaluated, implant design modifications altered simulated stress distribution across cortical and cancellous bone regions in low-density bone. Because specific configurations reduced cancellous stress while increasing peak cortical stress, design selection involves balancing localized cortical stress concentration with stress transmission into the underlying cancellous bone.

Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine
MIT World Peace University (IN)
Good health and well-being
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Influence of thread profiles, microthreads, and cutting flutes on dental implant performance: A finite element study — Pankaj N. Dhatrak, Santosh Patil, et al. · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine (2026) | TGRS Research Map | TGRS