Smartphone-readable electrochromic aptasensor based on a bifunctional polyaniline interface for label-free cortisol detection

The development of portable and user-friendly biosensing platforms is important for decentralized monitoring of stress-related biomarkers. Herein, a smartphone-readable electrochromic aptasensor based on a bifunctional polyaniline (PANI) interface was developed for label-free cortisol detection. The PANI film was directly electropolymerized onto an ITO-based screen-printed electrode platform (ITO-SPE), where it functioned simultaneously as an electrochromic transducer and an aptamer-supporting layer. Owing to its reversible redox behavior, PANI converted electrical stimulation into a visible color change that was quantified by smartphone-based green-channel analysis. A cortisol-specific aptamer was covalently immobilized onto the PANI surface through glutaraldehyde-mediated coupling. Upon cortisol binding, the resulting cortisol–aptamer complex modulated interfacial ion/electron transport and suppressed the redox-driven electrochromic switching of PANI, enabling optical signal generation without external redox probes, enzymatic labels, or secondary reagents. Under optimal conditions, the aptasensor showed a logarithmic response over the cortisol concentration range of 1–100 nmol L −1 , with a regression-estimated detection limit of 0.18 nmol L −1 that was not independently confirmed experimentally. The platform demonstrated satisfactory selectivity toward cortisol over the investigated structurally related corticosteroids and biologically relevant potential interferents at the tested concentration levels, together with good device-to-device reproducibility and acceptable short-term storage stability. Matrix-effect evaluation and recovery analysis in 25-fold diluted human serum and saliva further indicated no statistically significant matrix-dependent differences at the evaluated cortisol concentrations and acceptable recovery performance. This work presents a simple and smartphone-readable electrochromic aptasensing platform for cortisol detection, with proof-of-concept applicability in diluted biological matrices and potential for future portable biomarker-analysis applications.

Authors

Institutions

Publication Details

Journal
Sensors International
Published
2026-11-25
DOI
https://doi.org/10.1016/j.sintl.2026.100415
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Smartphone-readable electrochromic aptasensor based on a bifunctional polyaniline interface for label-free cortisol detection

Chawin Srisomwat, Orawon Chailapakul, Supada Khonyoung, Warawut Tiyapongpattana et al.
4 links
Sensors International
Advanced biosensing and bioanalysis techniques
article

Smartphone-readable electrochromic aptasensor based on a bifunctional polyaniline interface for label-free cortisol detection

Chawin Srisomwat, Orawon Chailapakul, Supada Khonyoung, Warawut Tiyapongpattana, Passakorn Pomngoen, Sasiprapa Tathong
article en

Abstract

The development of portable and user-friendly biosensing platforms is important for decentralized monitoring of stress-related biomarkers. Herein, a smartphone-readable electrochromic aptasensor based on a bifunctional polyaniline (PANI) interface was developed for label-free cortisol detection. The PANI film was directly electropolymerized onto an ITO-based screen-printed electrode platform (ITO-SPE), where it functioned simultaneously as an electrochromic transducer and an aptamer-supporting layer. Owing to its reversible redox behavior, PANI converted electrical stimulation into a visible color change that was quantified by smartphone-based green-channel analysis. A cortisol-specific aptamer was covalently immobilized onto the PANI surface through glutaraldehyde-mediated coupling. Upon cortisol binding, the resulting cortisol–aptamer complex modulated interfacial ion/electron transport and suppressed the redox-driven electrochromic switching of PANI, enabling optical signal generation without external redox probes, enzymatic labels, or secondary reagents. Under optimal conditions, the aptasensor showed a logarithmic response over the cortisol concentration range of 1–100 nmol L −1 , with a regression-estimated detection limit of 0.18 nmol L −1 that was not independently confirmed experimentally. The platform demonstrated satisfactory selectivity toward cortisol over the investigated structurally related corticosteroids and biologically relevant potential interferents at the tested concentration levels, together with good device-to-device reproducibility and acceptable short-term storage stability. Matrix-effect evaluation and recovery analysis in 25-fold diluted human serum and saliva further indicated no statistically significant matrix-dependent differences at the evaluated cortisol concentrations and acceptable recovery performance. This work presents a simple and smartphone-readable electrochromic aptasensing platform for cortisol detection, with proof-of-concept applicability in diluted biological matrices and potential for future portable biomarker-analysis applications.

Sensors InternationalVol. 8
Thammasat University (TH), Chulalongkorn University (TH)
National Research Council of Thailand, Thammasat University
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon