Minimum-Norm Inverse Least Squares (MILS) for Spectroscopic Calibration: How Optical Representations Control Full-Spectrum Prediction

Full-spectrum inverse calibration is usually considered unstable for vibrational spectra because the number of spectral variables greatly exceeds the number of calibration samples. Here, we formulate Minimum-norm Inverse Least Squares (MILS), which predicts concentration directly from the complete spectral matrix through the Moore−Penrose pseudoinverse, without wavelength selection or hyperparameter tuning. At the full identifiable rank of the centered calibration matrix, MILS is algebraically equivalent to PLS or PCR but obtains that solution directly, without rank selection. It is therefore both a robust default at small calibration set sizes and a clean probe of representation effects. We evaluate MILS on infrared and Raman spectra of binary liquid mixtures, using ATR-corrected complex refractive index and Kramers−Kronig representations, and on a public ATR-FTIR fermentation data set. Against nested PLS-best, fixed-rank PLS, and ridge regression, MILS is stable and competitive. Performance is controlled strongly by the optical representation: the full complex refractive index is favored where the non-resonant refractive-index contrast is small, the real component where it is larger, and Raman systems depend less. Absorbance-derived Kramers−Kronig complexification helps only modestly: the reconstruction reproduces the line shape but not the background, which centering annihilates. After re-inverting the reflectance under a single composition-independent background, the dispersive shape alone predicts composition 1.9 to 4.7 times more accurately than the absorption index where the latter is at the noise level, and direct subtraction gives a similar 1.9 to 6.0; over the full range, the background dominates, and it must come from an independent measurement rather than from the spectrum.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-11-25
DOI
https://doi.org/10.1021/acs.analchem.6c04207
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Minimum-Norm Inverse Least Squares (MILS) for Spectroscopic Calibration: How Optical Representations Control Full-Spectrum Prediction

Thomas G. Mayerhöfer, Jürgen Popp
2 links
Analytical Chemistry
Spectroscopy and Chemometric Analyses
article

Minimum-Norm Inverse Least Squares (MILS) for Spectroscopic Calibration: How Optical Representations Control Full-Spectrum Prediction

Thomas G. Mayerhöfer, Jürgen Popp
article en

Abstract

Full-spectrum inverse calibration is usually considered unstable for vibrational spectra because the number of spectral variables greatly exceeds the number of calibration samples. Here, we formulate Minimum-norm Inverse Least Squares (MILS), which predicts concentration directly from the complete spectral matrix through the Moore−Penrose pseudoinverse, without wavelength selection or hyperparameter tuning. At the full identifiable rank of the centered calibration matrix, MILS is algebraically equivalent to PLS or PCR but obtains that solution directly, without rank selection. It is therefore both a robust default at small calibration set sizes and a clean probe of representation effects. We evaluate MILS on infrared and Raman spectra of binary liquid mixtures, using ATR-corrected complex refractive index and Kramers−Kronig representations, and on a public ATR-FTIR fermentation data set. Against nested PLS-best, fixed-rank PLS, and ridge regression, MILS is stable and competitive. Performance is controlled strongly by the optical representation: the full complex refractive index is favored where the non-resonant refractive-index contrast is small, the real component where it is larger, and Raman systems depend less. Absorbance-derived Kramers−Kronig complexification helps only modestly: the reconstruction reproduces the line shape but not the background, which centering annihilates. After re-inverting the reflectance under a single composition-independent background, the dispersive shape alone predicts composition 1.9 to 4.7 times more accurately than the absorption index where the latter is at the noise level, and direct subtraction gives a similar 1.9 to 6.0; over the full range, the background dominates, and it must come from an independent measurement rather than from the spectrum.

Analytical Chemistry
Leibniz Institute of Photonic Technology (DE), Friedrich Schiller University Jena (DE)
Spectroscopy and Chemometric Analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Minimum-Norm Inverse Least Squares (MILS) for Spectroscopic Calibration: How Optical Representations Control Full-Spectrum Prediction — Thomas G. Mayerhöfer, Jürgen Popp · Analytical Chemistry (2026) | TGRS Research Map | TGRS