Supply–Demand Matching Assessment of Cooling Services from Urban Green Spaces in a Tropical City with Remote Sensing

With increasingly deteriorating urban thermal environments, urban residents have a growing demand for the cooling services of urban green spaces (UGSs). However, the spatial pattern of the supply and demand of cooling services was still not well understood, especially in tropical cities. Based on our constructed Cooling Services Supply Index (CSI) and Cooling Services Demand Index (CDI), we quantitatively assessed the supply–demand matching in Haikou, a typical tropical city. The results showed that: (1) only 54.73% of UGS patches had a measurable cooling effect in this typical tropical city. The UGS cooling distance (CD) ranged from 17.80 to 545.20 m (mean: 231.98 m), and the cooling intensity (CI) ranged from 0.06 to 9.11 °C (mean: 1.92 °C). (2) High-supply cooling-service areas were mainly distributed near large parks, urban peripheries, and industrial zones, while high-demand areas were concentrated in densely built-up central urban areas. Subdistricts in the old urban area showed high demand and low supply, whereas those in new urban areas or suburbs showed moderate surplus and low demand. (3) At the block scale, deficit, mid-deficit, and zero-supply, covering 79.63% of the population, and 91.56% of blocks and 86.81% of the population, remained below good or excellent coordination. At the subdistrict scale, five subdistricts achieved a balanced supply–demand relationship, and five reached a relatively high coordination level. (4) In central Haikou, 50.64% of the 1102 blocks were anomalous. Priority areas covered 36.31% of the population, and zero-supply, deficit-disorder, and deficit-near-disorder accounted for 97.51% of the priority-area population, indicating that critical cooling conflicts occur in densely populated areas. This study can provide strategic support for green space planning and management, as well as thermal environment governance in tropical cities.

Authors

Institutions

Publication Details

Journal
Land
Published
2026-11-24
DOI
https://doi.org/10.3390/land15122270
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Supply–Demand Matching Assessment of Cooling Services from Urban Green Spaces in a Tropical City with Remote Sensing

Yunxia Du, Ya Huang, Zhibin Ren, Yingying Zhang
Land
Urban Heat Island Mitigation
article

Supply–Demand Matching Assessment of Cooling Services from Urban Green Spaces in a Tropical City with Remote Sensing

Yunxia Du, Ya Huang, Zhibin Ren, Yingying Zhang
article en

Abstract

With increasingly deteriorating urban thermal environments, urban residents have a growing demand for the cooling services of urban green spaces (UGSs). However, the spatial pattern of the supply and demand of cooling services was still not well understood, especially in tropical cities. Based on our constructed Cooling Services Supply Index (CSI) and Cooling Services Demand Index (CDI), we quantitatively assessed the supply–demand matching in Haikou, a typical tropical city. The results showed that: (1) only 54.73% of UGS patches had a measurable cooling effect in this typical tropical city. The UGS cooling distance (CD) ranged from 17.80 to 545.20 m (mean: 231.98 m), and the cooling intensity (CI) ranged from 0.06 to 9.11 °C (mean: 1.92 °C). (2) High-supply cooling-service areas were mainly distributed near large parks, urban peripheries, and industrial zones, while high-demand areas were concentrated in densely built-up central urban areas. Subdistricts in the old urban area showed high demand and low supply, whereas those in new urban areas or suburbs showed moderate surplus and low demand. (3) At the block scale, deficit, mid-deficit, and zero-supply, covering 79.63% of the population, and 91.56% of blocks and 86.81% of the population, remained below good or excellent coordination. At the subdistrict scale, five subdistricts achieved a balanced supply–demand relationship, and five reached a relatively high coordination level. (4) In central Haikou, 50.64% of the 1102 blocks were anomalous. Priority areas covered 36.31% of the population, and zero-supply, deficit-disorder, and deficit-near-disorder accounted for 97.51% of the priority-area population, indicating that critical cooling conflicts occur in densely populated areas. This study can provide strategic support for green space planning and management, as well as thermal environment governance in tropical cities.

LandVol. 15(12)
Hainan Normal University (CN), Chinese Academy of Sciences (CN), Northeast Institute of Geography and Agroecology (CN)
Urban Heat Island Mitigation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon