Microresonance: Wireless 802.11 TSF-Coherent Active Acoustic Probing of the Skeletal Waveguide for Real-Time Isometric Motor Intent and Posture Decoupling

Non-invasive extraction of voluntary motor intent via surface electromyography (sEMG) suffers from skin-electrode impedance drift, sweat degradation, inability to operate through clothing, and severe baseline saturation under orthostatic load. We present Microresonance, a dry, through-clothing wireless neuromuscular interface (< $100 prototype BOM) that treats the limb as a low-loss skeletal waveguide (bone) shunt-loaded by tunable viscoelastic muscle-tendon resonators. Two untethered ESP32-S3 nodes achieve sub-2 µs wireless clock coherency via hardware IEEE 802.11 TSF timestamps, yielding a 3.01° resting phase noise floor at 33.4 Hz (30 ms latency). Across seated, leg-extended, and standing orthostatic regimes, 500 Hz acoustic phase achieves 28.2–33.0 dB non-circular protocol-frequency SNR (0.10 Hz), outperforming concurrent sEMG by 18.1–26.7 dB and IMU tilt by 9.8–12.4 dB, while inter-axis polarization classifies limb posture with 100.0% IMU-free holdout accuracy. Patent Disclosure: WO/2026/229867 (PCT/IB2026/054169). Code & Raw Data: [https://github.com/itsme228/microresonance](https://github.com/itsme228/microresonance)

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-25
DOI
https://doi.org/10.5281/zenodo.24533995
Primary Topic
Muscle activation and electromyography studies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Microresonance: Wireless 802.11 TSF-Coherent Active Acoustic Probing of the Skeletal Waveguide for Real-Time Isometric Motor Intent and Posture Decoupling

Amir Fatkulin
Zenodo (CERN European Organization for Nuclear Research)
Muscle activation and electromyography studies
preprint

Microresonance: Wireless 802.11 TSF-Coherent Active Acoustic Probing of the Skeletal Waveguide for Real-Time Isometric Motor Intent and Posture Decoupling

Amir Fatkulin
preprint en

Abstract

Non-invasive extraction of voluntary motor intent via surface electromyography (sEMG) suffers from skin-electrode impedance drift, sweat degradation, inability to operate through clothing, and severe baseline saturation under orthostatic load. We present Microresonance, a dry, through-clothing wireless neuromuscular interface (< $100 prototype BOM) that treats the limb as a low-loss skeletal waveguide (bone) shunt-loaded by tunable viscoelastic muscle-tendon resonators. Two untethered ESP32-S3 nodes achieve sub-2 µs wireless clock coherency via hardware IEEE 802.11 TSF timestamps, yielding a 3.01° resting phase noise floor at 33.4 Hz (30 ms latency). Across seated, leg-extended, and standing orthostatic regimes, 500 Hz acoustic phase achieves 28.2–33.0 dB non-circular protocol-frequency SNR (0.10 Hz), outperforming concurrent sEMG by 18.1–26.7 dB and IMU tilt by 9.8–12.4 dB, while inter-axis polarization classifies limb posture with 100.0% IMU-free holdout accuracy. Patent Disclosure: WO/2026/229867 (PCT/IB2026/054169). Code & Raw Data: [https://github.com/itsme228/microresonance](https://github.com/itsme228/microresonance)

Zenodo (CERN European Organization for Nuclear Research)
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon