Monte Carlo and Machine Learning Analysis of Multidirectional Neutron Shielding in Layered Concrete Accelerator Tunnels over a Soil-Embedded Concrete Base
Secondary neutron fields generated by high-energy proton–target interactions constitute one of the major radiation components that must be considered in the design of shielding systems for accelerator facilities. In this study, the multidirectional transport of secondary neutrons produced by the interaction of 1000 MeV protons with a copper target, together with the associated spatial attenuation characteristics of ambient dose equivalent H*(10), was investigated within a tunnel-type accelerator geometry. The shielding geometry comprised concrete side walls modeled as successive layers, a monolithic concrete base block, and a surrounding soil region, enabling neutron transport to be evaluated in both the horizontal and vertical directions. A dataset consisting of 1158 spatial data points was generated from high-fidelity ambient dose equivalent H*(10) distributions calculated using FLUKA Monte Carlo (MC) simulations and was subsequently employed to develop regression-based machine learning (ML) surrogate models. For the ML analysis, spatial distance along the investigated horizontal and vertical directions was used as the predictor variable, while the corresponding FLUKA-calculated H*(10) value was used as the target variable. The ETR, RF, GBR, HGBR, and KNN algorithms were trained and evaluated using a 10-fold cross-validation procedure. All models reproduced the FLUKA-derived H*(10) distributions with high predictive accuracy (R² > 0.98), with the most stable predictive performance achieved by the tree-based ensemble models.The FLUKA results demonstrated a distance-dependent reduction in ambient dose equivalent H*(10) across the modeled concrete shielding regions and revealed pronounced directional variations in neutron transport within the investigated concrete-soil geometry. Since the adjacent concrete layers were defined with identical elemental composition and density, the calculated attenuation behavior was not interpreted as arising from an additional physical scattering mechanism associated with the boundaries between these layers. Furthermore, because a controlled comparison with a monolithic concrete reference configuration having identical total thickness and material properties was not performed, no inference was made regarding superior shielding performance of the layered geometry relative to monolithic concrete. Accordingly, the present results characterize the multidirectional neutron transport and H*(10) distributions of the investigated concrete-soil shielding geometry under 1000 MeV proton irradiation conditions. The findings demonstrate that integrating MC simulations with ML-based surrogate modeling provides a practical and computationally efficient approach for rapid H*(10) prediction and shielding assessment within the investigated fixed irradiation and shielding configuration.
Authors
- Demet Sarıyer (ORCID: https://orcid.org/0000-0002-7803-111X)
- Elif Yıldırım (ORCID: https://orcid.org/0000-0002-1599-9473)
Institutions
- Manisa Celal Bayar University (TR)
- Istanbul Technical University (TR)
Publication Details
- Journal
- Süleyman Demirel Üniversitesi Fen Edebiyat Fakültesi Fen Dergisi
- Published
- 2026-11-25
- DOI
- https://doi.org/10.29233/sdufeffd.1910334
- Primary Topic
- Radiation Shielding Materials Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Türkiye Bilimsel ve Teknolojik Araştırma Kurumu