Reduced microbial touch transmission by engineering the microtopography of medical glove surfaces

Touch transmission of pathogens is a major contributor to the spread of infectious disease within hospitals as health care workers interact with patients and the environment. Reducing microbial transmission by touch contact can reduce rates of health care–associated infections. We modified commercial medical gloves with superhydrophobic (Cassie-Baxter) microtopographies to test rates of microbial attachment and transmission through touch contact with contaminated fomite surfaces. Molded post and groove topographies with critical dimensions between 2.5 and 15 micrometers were evaluated through compressive touch experiments with six clinically relevant microbial species (Candida albicans, Enterococcus faecium, Escherichia coli, Klebsiella pneumoniae, Staphylococcus aureus, and Staphylococcus epidermidis). After compressive contact (1- to 9-newton force), results showed an average reduction of 1.65 log (97.8%) in cells transferred to post or straight-walled groove–modified gloves compared with unmodified gloves, for all species (P < 0.0001). For sequential touch transmission to multiple surfaces, there was a 1.8 to 2.0 log (98.4 to 99%) reduction in S. aureus and K. pneumoniae transferred to modified gloves compared with controls. Transfer efficiencies fell from 43.6 ± 12.2% to 1.79 ± 0.70% (P10) and 1.75 ± 0.48% (SW15) for S. aureus (P < 0.001), with comparable reductions for K. pneumoniae. Touch transmission from dry biofilms and hospital bedrail surfaces was similarly reduced. The mechanisms underlying this nonspecific microbial repellency were reduction in physical transfer of contaminated fluids and limited surface area for microbial attachment. These reductions in microbial attachment and transfer for topography-modified gloves may contribute to reducing pathogen transmission within hospitals.

Authors

Institutions

Publication Details

Journal
Science Translational Medicine
Published
2026-11-25
DOI
https://doi.org/10.1126/scitranslmed.aee8043
Primary Topic
Infection Control in Healthcare
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Reduced microbial touch transmission by engineering the microtopography of medical glove surfaces

Alexa Zayadi, Benjamin D. Hatton, Xena X. Li, Desmond van den Berg et al.
1 links
Science Translational Medicine
Infection Control in Healthcare
article

Reduced microbial touch transmission by engineering the microtopography of medical glove surfaces

Alexa Zayadi, Benjamin D. Hatton, Xena X. Li, Desmond van den Berg, Dalal Asker, Kevin C. Katz, Elisa Sohrmann
article en

Abstract

Touch transmission of pathogens is a major contributor to the spread of infectious disease within hospitals as health care workers interact with patients and the environment. Reducing microbial transmission by touch contact can reduce rates of health care–associated infections. We modified commercial medical gloves with superhydrophobic (Cassie-Baxter) microtopographies to test rates of microbial attachment and transmission through touch contact with contaminated fomite surfaces. Molded post and groove topographies with critical dimensions between 2.5 and 15 micrometers were evaluated through compressive touch experiments with six clinically relevant microbial species (Candida albicans, Enterococcus faecium, Escherichia coli, Klebsiella pneumoniae, Staphylococcus aureus, and Staphylococcus epidermidis). After compressive contact (1- to 9-newton force), results showed an average reduction of 1.65 log (97.8%) in cells transferred to post or straight-walled groove–modified gloves compared with unmodified gloves, for all species (P < 0.0001). For sequential touch transmission to multiple surfaces, there was a 1.8 to 2.0 log (98.4 to 99%) reduction in S. aureus and K. pneumoniae transferred to modified gloves compared with controls. Transfer efficiencies fell from 43.6 ± 12.2% to 1.79 ± 0.70% (P10) and 1.75 ± 0.48% (SW15) for S. aureus (P < 0.001), with comparable reductions for K. pneumoniae. Touch transmission from dry biofilms and hospital bedrail surfaces was similarly reduced. The mechanisms underlying this nonspecific microbial repellency were reduction in physical transfer of contaminated fluids and limited surface area for microbial attachment. These reductions in microbial attachment and transfer for topography-modified gloves may contribute to reducing pathogen transmission within hospitals.

Science Translational MedicineVol. 18(877)
University of Toronto (CA), North York General Hospital (CA), Alexandria University (EG)
University of Toronto, Connaught Fund, Natural Sciences and Engineering Research Council of Canada
Good health and well-being
Infection Control in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon