40 Hz SSVEP-BCI with Code Words Encoding, Long-Short-Term Decoding, and Cross-Subject Transfer Learning for Minimal Calibration

High-frequency (HF) stimulation is a key strategy for reducing visual fatigue and enhancing user comfort in steady-state visual evoked potential (SSVEP) based brain-computer interfaces (BCIs). However, existing encoding and decoding methods often fail to meet the composite requirements of high classification accuracy, low training cost, and robust practical performance. To address these challenges, this study proposes a set of codec strategies, including a paradigm termed Code Words (CW), a Long-Short-Term Decoding (LSTD) method, and a general cross-subject transfer learning framework. The CW paradigm uses 40 Hz stimuli with opposing phases (0 and π) as two code elements to develop a 40-target visual BCI system. The LSTD method enables high-quality modeling of CW signals using only a single training block. In offline experiments with twenty subjects, LSTD improved the average classification accuracy by up to 9.48%. Furthermore, transfer learning reduces calibration data requirements, providing an additional 5.06% improvement in average accuracy. To evaluate the core system's stability, online experiments were conducted using the intra-subject LSTD strategy, during which 10 participants achieved an average accuracy of 93.17 ± 3.20% and an average information transfer rate (ITR) of 162.78 ± 10.05 bits/min. These results demonstrate that the intra-subject LSTD strategy delivers leading performance, while the integrated transfer learning framework further enhances robustness in minimal-calibration settings. Combined with transfer learning, the proposed framework significantly reduces calibration costs, demonstrating considerable potential for promoting the practical application of SSVEP-BCIs.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2026-11-25
DOI
https://doi.org/10.1109/jbhi.2026.3757399
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

40 Hz SSVEP-BCI with Code Words Encoding, Long-Short-Term Decoding, and Cross-Subject Transfer Learning for Minimal Calibration

Dong Ming, Haiqing Yu, Tzyy‐Ping Jung, Qiaoyi Wu et al.
2 links
IEEE Journal of Biomedical and Health Informatics
EEG and Brain-Computer Interfaces
article

40 Hz SSVEP-BCI with Code Words Encoding, Long-Short-Term Decoding, and Cross-Subject Transfer Learning for Minimal Calibration

Dong Ming, Haiqing Yu, Tzyy‐Ping Jung, Qiaoyi Wu, Minpeng Xu, Yongzhi Huang
article en

Abstract

High-frequency (HF) stimulation is a key strategy for reducing visual fatigue and enhancing user comfort in steady-state visual evoked potential (SSVEP) based brain-computer interfaces (BCIs). However, existing encoding and decoding methods often fail to meet the composite requirements of high classification accuracy, low training cost, and robust practical performance. To address these challenges, this study proposes a set of codec strategies, including a paradigm termed Code Words (CW), a Long-Short-Term Decoding (LSTD) method, and a general cross-subject transfer learning framework. The CW paradigm uses 40 Hz stimuli with opposing phases (0 and π) as two code elements to develop a 40-target visual BCI system. The LSTD method enables high-quality modeling of CW signals using only a single training block. In offline experiments with twenty subjects, LSTD improved the average classification accuracy by up to 9.48%. Furthermore, transfer learning reduces calibration data requirements, providing an additional 5.06% improvement in average accuracy. To evaluate the core system's stability, online experiments were conducted using the intra-subject LSTD strategy, during which 10 participants achieved an average accuracy of 93.17 ± 3.20% and an average information transfer rate (ITR) of 162.78 ± 10.05 bits/min. These results demonstrate that the intra-subject LSTD strategy delivers leading performance, while the integrated transfer learning framework further enhances robustness in minimal-calibration settings. Combined with transfer learning, the proposed framework significantly reduces calibration costs, demonstrating considerable potential for promoting the practical application of SSVEP-BCIs.

IEEE Journal of Biomedical and Health InformaticsVol. PP
Tianjin University (CN), University of California System (US)
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon