Field-relevant metrological performance of water meters: a topical review for water-infrastructure monitoring

Water meters are distributed measurement instruments whose readings support demand estimation, water balances, non-revenue water assessment and infrastructure monitoring. Their installed performance, however, may depart from the reference error curve established under controlled and traceable test conditions. This Topical Review synthesises evidence on the influence quantities that affect water-meter indication and the validity of extrapolating laboratory performance to field operation. A structured audit of Scopus and the Web of Science Core Collection retrieved 1,046 records. DOI- and title-based deduplication yielded 645 unique database records, and one additional experimental study was identified through citation tracking. Forty-nine scientific sources were retained as core evidence, supplemented by standards and other cited background literature that are not included in the core-evidence count. The evidence was organised around installation and accessories, flow-rate distribution, intermittent and dynamic operation, pressure and air, water quality, ageing and measurement technology. Across these dimensions, the sign and magnitude of error were strongly dependent on meter model, internal architecture, diameter and operating context. Low-flow exposure, disturbed inlet conditions, short events, partial valve closure, air passage, deposits and ageing can produce under-registration, over-registration, irregular response or non-registration, but the literature does not support universal correction factors or technology rankings. The review therefore proposes assessment dimensions to determine when a reference error curve may be insufficiently representative and when inspection, post-removal testing, traceable laboratory verification or local validation should be prioritised. The resulting framework supports documentation and decision-making; it is not a calibrated prediction model. The principal gaps concern long-term evidence for solid-state domestic meters, combined disturbances, field-valid uncertainty assessment and interlaboratory comparability.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2026-11-25
DOI
https://doi.org/10.1088/1361-6501/aec6bf
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Field-relevant metrological performance of water meters: a topical review for water-infrastructure monitoring

Gustavo Adolfo Esteban, Urko Izquierdo, Iñigo Bidaguren, Iñigo Albaina et al.
1 links
Measurement Science and Technology
Flow Measurement and Analysis
article

Field-relevant metrological performance of water meters: a topical review for water-infrastructure monitoring

Gustavo Adolfo Esteban, Urko Izquierdo, Iñigo Bidaguren, Iñigo Albaina, Alberto Peña
article en

Abstract

Water meters are distributed measurement instruments whose readings support demand estimation, water balances, non-revenue water assessment and infrastructure monitoring. Their installed performance, however, may depart from the reference error curve established under controlled and traceable test conditions. This Topical Review synthesises evidence on the influence quantities that affect water-meter indication and the validity of extrapolating laboratory performance to field operation. A structured audit of Scopus and the Web of Science Core Collection retrieved 1,046 records. DOI- and title-based deduplication yielded 645 unique database records, and one additional experimental study was identified through citation tracking. Forty-nine scientific sources were retained as core evidence, supplemented by standards and other cited background literature that are not included in the core-evidence count. The evidence was organised around installation and accessories, flow-rate distribution, intermittent and dynamic operation, pressure and air, water quality, ageing and measurement technology. Across these dimensions, the sign and magnitude of error were strongly dependent on meter model, internal architecture, diameter and operating context. Low-flow exposure, disturbed inlet conditions, short events, partial valve closure, air passage, deposits and ageing can produce under-registration, over-registration, irregular response or non-registration, but the literature does not support universal correction factors or technology rankings. The review therefore proposes assessment dimensions to determine when a reference error curve may be insufficiently representative and when inspection, post-removal testing, traceable laboratory verification or local validation should be prioritised. The resulting framework supports documentation and decision-making; it is not a calibrated prediction model. The principal gaps concern long-term evidence for solid-state domestic meters, combined disturbances, field-valid uncertainty assessment and interlaboratory comparability.

Measurement Science and Technology
University of the Basque Country (ES)
Clean water and sanitation
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.