A machine-readable specification of the ISOS stability protocols, with protocol classification and refusing degradation metrics for perovskite photovoltaics
The ISOS consensus protocols define how accelerated stability tests on perovskite and organic photovoltaic devices should be run and reported, but they exist as prose and tables rather than as anything a machine can check. Two failures follow. Reported test conditions frequently do not determine a protocol designation, and the gap is usually one or two specific conditions that were never stated. Separately, the lifetime figure T80 denotes at least three distinct quantities, differing in which performance value is taken as the reference and when the clock starts, and published values are rarely qualified by which was used. We present isoskit, an open Python package that encodes 33 ISOS protocols as a versioned machine-readable specification with a JSON Schema, classifies a reported measurement into its protocol designation or names the conditions preventing designation, and extracts lifetime figures of merit under explicitly named reference conventions, returning a structured refusal wherever the reported measurement does not support extraction. Using the encoded specification we report three computational results. First, round-trip validation shows that 27 of 33 protocols are uniquely identifiable from their tabulated stress conditions; the remaining six form three degenerate pairs whose distinction lies in equipment and cycle profile rather than in stress conditions, one of which is induced by the encoding of inert-atmosphere humidity. Second, an exhaustive ablation over all 270,336 combinations of withheld conditions identifies six conditions without which no protocol in the set can be designated, and shows that withholding a single condition reduces the designated fraction from 81.8 % to 25.9 %. Third, on a two-phase ageing model the reference conventions diverge by a factor of 10.4 at a burn-in depth of 25 %, while linear interpolation of the crossing time remains accurate to 2 h at a 400 h measurement interval for which the defensible bracketing uncertainty is 400 h. The package is MIT licensed, has no runtime dependencies, and generates its own reference documentation from the specification.
Authors
- Edmond Kwesi Dadson
- Abdulai Rabiu (ORCID: https://orcid.org/0000-0002-3739-140X)
Institutions
- University of Toledo (US)
Publication Details
- Journal
- ChemRxiv
- Published
- 2026-11-25
- DOI
- https://doi.org/10.26434/chemrxiv.15012758/v1
- Primary Topic
- Perovskite Materials and Applications
- Type
- preprint