Static guided versus freehand techniques for fiber post removal: a comparative in vitro study
To evaluate static guided digital technique and compare it with freehand techniques for fiber post removal, using Peeso reamers and ultrasonic diamond-coated instruments. Thirty-two extracted double-rooted maxillary premolars were endodontically treated ex vivo. Post space preparation and fiber post cementation were performed in the palatal canal following standardized protocols. The samples were randomly allocated into four groups based on the post removal method and instrument used (n = 8): peeso guided, ultrasonic guided, peeso freehand, and ultrasonic freehand. For the guided groups, virtual drill-and-guide planning was performed after superimposing CBCT and digital surface scans, and the guides were fabricated using three-dimensional printing. The drilling and total time taken to remove the fiber post were recorded. A postoperative CBCT was used to assess deviation between the planned and actual drill paths, remaining dentin thickness, and mishaps. Statistical analysis was performed using two-way factorial ANOVA with robust standard errors and Holm-corrected post-hoc tests (α = 0.05). Significant instrument type effects were found for coronal (p = 0.002 ), middle (p = 0.003 ), and total deviation (p = 0.027), with significant instrument $$\:\times\:$$ technique interactions at coronal (p = 0.043) and middle (p = 0.040) levels. The Peeso guided protocol exhibited the lowest total deviation ($$\:0.325\pm\:0.148\;\text{mm}$$). Significant differences in RDT% were observed for main effects and interaction (p < 0.001). Peeso guided preserved the most dentin ($$\:95.62\%\pm\:2.14\%$$), followed by Ultrasonic freehand ($$\:91.39\%\pm\:2.85\%$$), Peeso freehand ($$\:88.47\%\pm\:3.12\%$$), and Ultrasonic guided ($$\:86.82\%\pm\:3.41\%$$). Drilling and total times differed significantly (p < 0.001), with Peeso guided requiring the shortest duration ($$\:30.0\pm\:4.3\;\text{s}$$) and Ultrasonic guided requiring the longest ($$\:685.4\pm\:37.7\;\text{s}$$). One root perforation occurred in the ultrasonic freehand group. Fiber post removal outcomes are multifactorial and primarily influenced by instrument-technique interaction. Therefore, optimal clinical performance of static guides relies on integrating appropriate instrument mechanics.
Authors
- Tarek Medhat Elsewify (ORCID: https://orcid.org/0000-0001-9266-7838)
- Ranya Faraj Elemam (ORCID: https://orcid.org/0000-0002-3220-0563)
- Bassem M. Eid (ORCID: https://orcid.org/0000-0002-4822-5503)
- Diaaeldin Farag (ORCID: https://orcid.org/0000-0002-2266-740X)
- B. Mohamad (ORCID: https://orcid.org/0009-0004-1398-2741)
Institutions
- Ain Shams University (EG)
- Suez Canal University (EG)
- Gulf Medical University (AE)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-11-25
- DOI
- https://doi.org/10.1038/s41598-026-80162-4
- Primary Topic
- Dental materials and restorations
- Type
- article
- Field-Weighted Citation Impact
- 0.00