ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE SIMULTANEOUS ESTIMATION OF AMLODIPINE AND VALSARTAN IN BULK AND PHARMACEUTICAL DOSAGE FORM BY RP-HPLC METHOD

A rapid, sensitive and accurate RP-HPLC method was developed for the identification and quantification of Amlodipine and Valsartan using a Waters HPLC system equipped with a PDA detector. Chromatographic separation was achieved on an Inertsil ODS-C18 column (150 × 4.6 mm, 5 µm particle size) with a flow rate of 1.0 mL/min. The mobile phase consisted of degassed and filtered Water and Triethylamine (1000: 10) with pH of 2.8 adjusted with phosphoric acid (Solution-A) and Methanol:Acetonitrile (700: 300) (Solution-B). Detection was performed at 240 nm, providing reliable resolution and measurement of both analytes.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-25
DOI
https://doi.org/10.5281/zenodo.24527841
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE SIMULTANEOUS ESTIMATION OF AMLODIPINE AND VALSARTAN IN BULK AND PHARMACEUTICAL DOSAGE FORM BY RP-HPLC METHOD

P. Uma Devi, P V Madhavi Latha, K. Suvarna, Ratti Bhavani
2 links
Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE SIMULTANEOUS ESTIMATION OF AMLODIPINE AND VALSARTAN IN BULK AND PHARMACEUTICAL DOSAGE FORM BY RP-HPLC METHOD

P. Uma Devi, P V Madhavi Latha, K. Suvarna, Ratti Bhavani
article en

Abstract

A rapid, sensitive and accurate RP-HPLC method was developed for the identification and quantification of Amlodipine and Valsartan using a Waters HPLC system equipped with a PDA detector. Chromatographic separation was achieved on an Inertsil ODS-C18 column (150 × 4.6 mm, 5 µm particle size) with a flow rate of 1.0 mL/min. The mobile phase consisted of degassed and filtered Water and Triethylamine (1000: 10) with pH of 2.8 adjusted with phosphoric acid (Solution-A) and Methanol:Acetonitrile (700: 300) (Solution-B). Detection was performed at 240 nm, providing reliable resolution and measurement of both analytes.

Zenodo (CERN European Organization for Nuclear Research)
Good health and well-being
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon