PCL/Arginine Nanofiber‐Based Wearable Triboelectric Sensor for Real‐Time Finger Tremor Monitoring and State Classification
Finger tremor is an important motor manifestation of Parkinson's disease (PD), and objective characterization of tremor‐related finger motion is valuable for wearable movement monitoring. However, conventional clinical assessments are generally intermittent, highlighting the need for flexible sensing approaches capable of capturing transient finger‐motion signals. Here, we propose a wearable finger tremor monitoring and recognition system integrating a polycaprolactone/arginine (PCL/Arg) nanofiber‐based triboelectric sensor with gated recurrent unit (GRU) learning. The sensor adopts a multilayer vertical contact–separation structure consisting of a foam buffering pad, PCL/Arg positive triboelectric layer, polydimethylsiloxane (PDMS) negative triboelectric layer, Ecoflex spacer, Mg electrodes, and Kapton encapsulation. Arginine incorporation introduces polar functional groups and hydrogen‐bonding sites into the PCL nanofiber network, contributing to enhanced triboelectric output. Under an excitation frequency of 2 Hz and an applied force of 8 N, the optimized sensor containing 3 wt% Arg delivers an open‐circuit voltage of 213.93 V, a short‐circuit current of 32.8 μA, and a transferred charge of 109.74 nC, corresponding to enhancements of approximately 1.75, 2.27, and 2.04 times compared with pristine PCL, respectively. The device further exhibits a peak power density of 4.12 W m −2 at 50 MΩ, a sensitivity of 24.916 ± 0.3258 V kPa −1, a maximum linearity error of 2.481%, a response time of 15 ms, and a signal‐to‐noise ratio of 62.534 dB. Furthermore, a multichannel acquisition system was established to record finger‐motion signals, and a GRU network was employed to distinguish three labeled states, including normal, slight tremor, and serious tremor, achieving an overall classification accuracy of approximately 98.2% in the evaluated dataset. The experimental demonstration further illustrates real‐time signal acquisition, state recognition, and visual feedback. This work establishes a material–device–algorithm integrated approach for wearable finger tremor monitoring and intelligent motion‐state classification, providing a technical basis for future investigations of PD‐related motor symptoms.
Authors
- Xiuhan Li (ORCID: https://orcid.org/0000-0002-5254-9877)
- Peinian Zhang
- Yijun Hao (ORCID: https://orcid.org/0009-0009-3146-1903)
- Keke Hong
- Xiangqian Lu
- Zhao Guo
- Jiayu Su
- Xiaopeng Zhu (ORCID: https://orcid.org/0009-0007-5665-2947)
Institutions
- National University of Singapore (SG)
- Beijing Jiaotong University (CN)
Publication Details
- Journal
- FlexTech
- Published
- 2026-11-25
- DOI
- https://doi.org/10.1002/fle2.70027
- Primary Topic
- Advanced Sensor and Energy Harvesting Materials
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- China Scholarship Council
- Natural Science Foundation of Beijing Municipality
- National Natural Science Foundation of China-Shandong Joint Fund
- Fundamental Research Funds for the Central Universities