Construction and application of an RFID-based smart blood management system in the emergency department: a single-center quasi-experimental before-and-after study with historical controls

Objective To evaluate whether implementation of an integrated radio-frequency identification (RFID)-based smart blood-management program in the emergency department (ED) shortens blood-waiting time, improves the transfusion timeliness rate, reduces blood-retrieval frequency, and optimizes the efficiency of the transfusion workflow. Methods We conducted a single-center, quasi-experimental before-and-after study with historical controls. The pre-implementation cohort comprised 261 patients (714 blood units) managed with the conventional transfusion workflow between January and December 2023; the post-implementation cohort comprised 308 patients (509 blood units) managed with the integrated RFID-based smart blood-management program between January and December 2024. The program integrated RFID tags, an Internet-of-Things blood-storage refrigerator, an RFID-enabled transport box, a smart management platform, standardized staff training, and workflow reengineering. Results Age and sex were balanced between the groups (both P > 0.05), whereas the blood-component distribution differed significantly (P < 0.001) and was adjusted for in all subsequent models. Implementation of the integrated program was associated with a shorter blood-waiting time (46.56 ± 12.94 vs. 57.10 ± 16.69 min; GEE-adjusted difference −10.29 min, 95% CI −12.40 to −8.18) and a shorter blood-retrieval time (9.96 ± 1.87 vs. 15.85 ± 2.63 min; GEE-adjusted difference −5.89 min, 95% CI −6.16 to −5.62). The transfusion timeliness rate (cross-match-to-issuance ≤ 60 min) increased from 60.2% (95% CI 56.6–63.8) to 84.7% (95% CI 81.3–87.5), an absolute difference of 24.5 percentage points (95% CI 19.6–29.1; number needed to treat = 4). Blood-retrieval frequency decreased modestly from 100% to 95.63%. Subgroup analyses showed consistent improvements across red cell, plasma, and platelet transfusions, with the largest absolute reduction in the platelet subgroup (−21.0 min). Conclusion The program converts the manual dependence and information discontinuities of the traditional transfusion workflow into a continuous, visualized, and traceable data chain, providing a feasible digital solution for improving the efficiency and safety of emergency blood transfusion.

Authors

Institutions

Publication Details

Journal
Frontiers in Medicine
Published
2026-11-25
DOI
https://doi.org/10.3389/fmed.2026.1914662
Primary Topic
Blood donation and transfusion practices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Construction and application of an RFID-based smart blood management system in the emergency department: a single-center quasi-experimental before-and-after study with historical controls

Cong Cheng, Yang Li, Rongrong Shi, Min Wang et al.
1 links
Frontiers in Medicine
Blood donation and transfusion practices
article

Construction and application of an RFID-based smart blood management system in the emergency department: a single-center quasi-experimental before-and-after study with historical controls

Cong Cheng, Yang Li, Rongrong Shi, Min Wang, Qi Peng, Jianli Bao
article en

Abstract

Objective To evaluate whether implementation of an integrated radio-frequency identification (RFID)-based smart blood-management program in the emergency department (ED) shortens blood-waiting time, improves the transfusion timeliness rate, reduces blood-retrieval frequency, and optimizes the efficiency of the transfusion workflow. Methods We conducted a single-center, quasi-experimental before-and-after study with historical controls. The pre-implementation cohort comprised 261 patients (714 blood units) managed with the conventional transfusion workflow between January and December 2023; the post-implementation cohort comprised 308 patients (509 blood units) managed with the integrated RFID-based smart blood-management program between January and December 2024. The program integrated RFID tags, an Internet-of-Things blood-storage refrigerator, an RFID-enabled transport box, a smart management platform, standardized staff training, and workflow reengineering. Results Age and sex were balanced between the groups (both P > 0.05), whereas the blood-component distribution differed significantly (P < 0.001) and was adjusted for in all subsequent models. Implementation of the integrated program was associated with a shorter blood-waiting time (46.56 ± 12.94 vs. 57.10 ± 16.69 min; GEE-adjusted difference −10.29 min, 95% CI −12.40 to −8.18) and a shorter blood-retrieval time (9.96 ± 1.87 vs. 15.85 ± 2.63 min; GEE-adjusted difference −5.89 min, 95% CI −6.16 to −5.62). The transfusion timeliness rate (cross-match-to-issuance ≤ 60 min) increased from 60.2% (95% CI 56.6–63.8) to 84.7% (95% CI 81.3–87.5), an absolute difference of 24.5 percentage points (95% CI 19.6–29.1; number needed to treat = 4). Blood-retrieval frequency decreased modestly from 100% to 95.63%. Subgroup analyses showed consistent improvements across red cell, plasma, and platelet transfusions, with the largest absolute reduction in the platelet subgroup (−21.0 min). Conclusion The program converts the manual dependence and information discontinuities of the traditional transfusion workflow into a continuous, visualized, and traceable data chain, providing a feasible digital solution for improving the efficiency and safety of emergency blood transfusion.

Frontiers in MedicineVol. 13
Qingdao University (CN), Affiliated Hospital of Qingdao University (CN), Qingdao Municipal Hospital (CN), University of Health and Rehabilitation Sciences (CN)
Good health and well-being
Blood donation and transfusion practices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon