Toward Improved Assessment of Photovoltaic Module Enhancers: A New Lifespan and Cost-Effectiveness Factor

Photovoltaic (PV) enhancement technologies can improve electrical power output; however, their practical effectiveness depends on additional manufacturing costs and the operational lifespan of the enhancement devices. Although several assessment methods have been developed to evaluate PV enhancement technologies, simplified cost–power assessment approaches may not explicitly account for differences between PV module and enhancer lifespans. To address this limitation, the present study proposes the Lifespan and Cost Effectiveness Factor (FLCPE), which extends the previously established Cost–Power Effectiveness Factor (FCPE) by incorporating a lifespan correction based on the ratio between the PV module lifespan and the effective enhancer lifespan. The proposed dimensionless factor integrates manufacturing cost, additional electrical power output, unit PV power cost, and operational lifespan into a simplified preliminary assessment framework. A theoretical minimum value of zero is established, while a unity internal screening threshold is adopted to distinguish favorable, neutral, and unfavorable screening results. The applicability of the proposed factor is examined through hypothetical PV enhancement scenarios, sensitivity analysis, and an experimental application involving a PV enhancement system. The experimental application demonstrates how measured electrical power improvement can be combined with manufacturing cost and assumed operational lifespan to calculate the proposed factor under specified assessment conditions. The results illustrate the influence of enhancer lifespan on the calculated effectiveness and highlight the importance of accounting for differences between PV module and enhancer service lives. The proposed FLCPE provides a focused preliminary assessment method under specified operating conditions and complements, rather than replaces, comprehensive lifecycle economic evaluation approaches such as the levelized cost of electricity and net present value.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2026-11-25
DOI
https://doi.org/10.3390/su182312012
Primary Topic
Photovoltaic Systems and Sustainability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Toward Improved Assessment of Photovoltaic Module Enhancers: A New Lifespan and Cost-Effectiveness Factor

Sakhr M. Sultan, Chih Ping Tso
5 links
Sustainability
Photovoltaic Systems and Sustainability
article

Toward Improved Assessment of Photovoltaic Module Enhancers: A New Lifespan and Cost-Effectiveness Factor

Sakhr M. Sultan, Chih Ping Tso
article en

Abstract

Photovoltaic (PV) enhancement technologies can improve electrical power output; however, their practical effectiveness depends on additional manufacturing costs and the operational lifespan of the enhancement devices. Although several assessment methods have been developed to evaluate PV enhancement technologies, simplified cost–power assessment approaches may not explicitly account for differences between PV module and enhancer lifespans. To address this limitation, the present study proposes the Lifespan and Cost Effectiveness Factor (FLCPE), which extends the previously established Cost–Power Effectiveness Factor (FCPE) by incorporating a lifespan correction based on the ratio between the PV module lifespan and the effective enhancer lifespan. The proposed dimensionless factor integrates manufacturing cost, additional electrical power output, unit PV power cost, and operational lifespan into a simplified preliminary assessment framework. A theoretical minimum value of zero is established, while a unity internal screening threshold is adopted to distinguish favorable, neutral, and unfavorable screening results. The applicability of the proposed factor is examined through hypothetical PV enhancement scenarios, sensitivity analysis, and an experimental application involving a PV enhancement system. The experimental application demonstrates how measured electrical power improvement can be combined with manufacturing cost and assumed operational lifespan to calculate the proposed factor under specified assessment conditions. The results illustrate the influence of enhancer lifespan on the calculated effectiveness and highlight the importance of accounting for differences between PV module and enhancer service lives. The proposed FLCPE provides a focused preliminary assessment method under specified operating conditions and complements, rather than replaces, comprehensive lifecycle economic evaluation approaches such as the levelized cost of electricity and net present value.

SustainabilityVol. 18(23)
Multimedia University (MY), National University of Malaysia (MY)
Affordable and clean energy, Industry, innovation and infrastructure
Photovoltaic Systems and Sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon