Supraglottic Airway Rescue After Endotracheal Tube Displacement During Craniotomy With Rigid Head Fixation: A Case Report
Endotracheal tube (ETT) displacement during neurosurgery is hazardous when rigid head fixation restricts airway access. A 53-year-old man underwent emergency craniotomy for an acute subdural hematoma with his head rotated in a skull clamp. Intraoperatively, capnography and delivered tidal volume were lost, and the ETT had clinically migrated out of the trachea. Repeat videolaryngoscopy provided no glottic view; an intubation attempt was esophageal, and oxygen saturation fell to 71%. A size 4 AuraGain laryngeal mask (Ambu, Ballerup, Denmark) restored ventilation and oxygenation. Two visually guided intubation attempts through the device failed. With the dura open and oxygen saturation restored, the team continued hematoma evacuation with a plan for immediate clamp release if ventilation failed. Arterial carbon dioxide partial pressure (PaCO₂) subsequently reached 72 mmHg. After closure, the clamp was removed, and an oral ETT was placed under flexible endoscopic guidance. This case shows that a supraglottic airway may provide rescue oxygenation during rigid head fixation but does not remove the need to assess ventilation, aspiration risk, and access to definitive rescue.