Low-Velocity Impact Damage and Residual Tensile Performance of CFRP Plates with Embedded Steel Wires

To investigate the low-velocity impact damage and post-impact tensile performance of carbon fiber-reinforced polymer (CFRP) plates with embedded steel wires, this study examined three steel-wire-reinforced CFRP (SCFRP) configurations with different steel-wire volume fractions. Drop-weight impact tests were conducted at nominal impact energies of 12–72 J, followed by uniaxial tensile tests on the impact-damaged specimens. A stage-dependent equivalent energy-dissipation model was developed by considering the contributions of carbon-fiber fracture, epoxy-matrix crushing, and local steel-wire deformation. The model was assessed using retained experimental groove-depth measurements. The results showed that impact damage was mainly concentrated in the surface carbon-fiber region at 12–24 J, whereas the measured groove depths exceeded the nominal steel-wire cover thickness at 36 J. At 12–48 J, the SCFRP plates generally exhibited greater groove depths than CFRP, while the opposite trend was observed at 60–72 J. Under the adopted equivalent contact assumptions, the model achieved an in-sample mean absolute percentage error of 1.83%, a root mean square error of 0.0108 mm, and a coefficient of determination of 0.9985. The post-impact tensile capacities of all configurations decreased with increasing impact energy. At 72 J, the individually tested SCFRP-1, SCFRP-2, and SCFRP-3 specimens exhibited post-impact tensile loads 9.75%, 11.62%, and 14.52% higher, respectively, than that of the corresponding individually tested CFRP specimen. These percentages represent individual-specimen comparisons rather than statistically established improvements in material performance. These findings provide an equivalent mechanical framework for interpreting the impact damage and post-impact tensile response of SCFRP plates within the investigated conditions.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-11-25
DOI
https://doi.org/10.3390/buildings16234714
Primary Topic
Mechanical Behavior of Composites
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Low-Velocity Impact Damage and Residual Tensile Performance of CFRP Plates with Embedded Steel Wires

朱万旭, Chengyang Xiong, Jiayi Li, Yachen Li
1 links
Buildings
Mechanical Behavior of Composites
article

Low-Velocity Impact Damage and Residual Tensile Performance of CFRP Plates with Embedded Steel Wires

朱万旭, Chengyang Xiong, Jiayi Li, Yachen Li
article en

Abstract

To investigate the low-velocity impact damage and post-impact tensile performance of carbon fiber-reinforced polymer (CFRP) plates with embedded steel wires, this study examined three steel-wire-reinforced CFRP (SCFRP) configurations with different steel-wire volume fractions. Drop-weight impact tests were conducted at nominal impact energies of 12–72 J, followed by uniaxial tensile tests on the impact-damaged specimens. A stage-dependent equivalent energy-dissipation model was developed by considering the contributions of carbon-fiber fracture, epoxy-matrix crushing, and local steel-wire deformation. The model was assessed using retained experimental groove-depth measurements. The results showed that impact damage was mainly concentrated in the surface carbon-fiber region at 12–24 J, whereas the measured groove depths exceeded the nominal steel-wire cover thickness at 36 J. At 12–48 J, the SCFRP plates generally exhibited greater groove depths than CFRP, while the opposite trend was observed at 60–72 J. Under the adopted equivalent contact assumptions, the model achieved an in-sample mean absolute percentage error of 1.83%, a root mean square error of 0.0108 mm, and a coefficient of determination of 0.9985. The post-impact tensile capacities of all configurations decreased with increasing impact energy. At 72 J, the individually tested SCFRP-1, SCFRP-2, and SCFRP-3 specimens exhibited post-impact tensile loads 9.75%, 11.62%, and 14.52% higher, respectively, than that of the corresponding individually tested CFRP specimen. These percentages represent individual-specimen comparisons rather than statistically established improvements in material performance. These findings provide an equivalent mechanical framework for interpreting the impact damage and post-impact tensile response of SCFRP plates within the investigated conditions.

BuildingsVol. 16(23)
Guilin University of Technology (CN), Southeast University (CN)
Science and Technology Department of Guangxi Zhuang Autonomous
Industry, innovation and infrastructure
Mechanical Behavior of Composites
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon