Diagnostic Performance of CA-125, the Risk of Malignancy Index (RMI), IOTA Simple Rules, the ADNEX Model, and the Ovarian-Adnexal Reporting and Data System (O-RADS) in the Preoperative Evaluation of Adnexal Masses: A Prospective Cohort Study in Syria
Background: Preoperative discrimination between benign and malignant adnexal masses is essential to optimize management and referral. No single test is universally adopted. This study evaluated the diagnostic accuracy of cancer antigen 125 (CA-125), the Risk of Malignancy Index 1 (RMI 1), the International Ovarian Tumor Analysis (IOTA) Simple Rules (SR), IOTA ADNEX, and the Ovarian-Adnexal Reporting and Data System (O-RADS) in Syrian women. Methodology: This prospective study included 75 patients scheduled for surgical excision of adnexal masses at the University Hospital of Obstetrics and Gynecology in Damascus. Patients underwent preoperative evaluation using serum CA-125 levels, RMI 1, IOTA SR, IOTA ADNEX, and O-RADS. Histopathology served as the reference standard. Diagnostic metrics were evaluated, and pairwise receiver operating characteristic (ROC) curve comparisons were performed using DeLong’s test with Holm-Bonferroni adjustment. Results: Histopathology confirmed 51 (68.0%) benign and 24 (32.0%) malignant lesions (mean age, 44.17 ± 13.89 years). CA-125 ≥35 U/mL yielded a sensitivity of 58.3% and a specificity of 76.5%; at ≥100 U/mL, sensitivity was 45.8% and specificity was 96.1%. RMI 1 ≥25 yielded a sensitivity of 91.7% and a specificity of 60.8%, whereas RMI 1 ≥200 yielded a sensitivity of 54.2% and a specificity of 92.2%. IOTA Simple Rules among classifiable cases (n = 62) yielded a sensitivity of 100.0% and a specificity of 90.0%; 13/75 cases (17.3%) were inconclusive. O-RADS ≥4 yielded a sensitivity of 100.0%, a specificity of 72.5%, and an accuracy of 81.3%. At the prespecified ADNEX risk threshold of ≥10%, sensitivity was 100.0%, specificity was 70.6%, and accuracy was 80.0%. In the primary paired DeLong analysis of 62 classifiable cases, no pairwise area under the curve (AUC) difference remained significant after Holm-Bonferroni adjustment (all adjusted p ≥ 0.072). In the sensitivity analysis of all 75 cases, ADNEX had a higher AUC than CA-125, RMI 1, and binary IOTA Simple Rules, but not O-RADS. Conclusions: All evaluated methods showed useful discriminatory performance, but the primary paired analysis did not demonstrate statistically significant AUC differences after correction. The handling of inconclusive IOTA Simple Rules results affected secondary comparisons; these findings require confirmation in larger external cohorts.
Authors
- Muhammad Nazir Yasmineh
- Rafif Hadakie
Institutions
- Damascus University (SY)
Publication Details
- Journal
- Cureus
- Published
- 2026-11-25
- DOI
- https://doi.org/10.7759/cureus.120251
- Primary Topic
- Ovarian cancer diagnosis and treatment
- Type
- article
- Field-Weighted Citation Impact
- 0.00