Resin composites for clear aligner attachments: staining resistance, whitening response, and degree of conversion

Objectives This study evaluated the staining resistance and whitening response of resin composites indicated for clear aligner attachment fabrication compared with restorative composites and characterized their polymerization kinetics. Methods Discs of Aligner Flow LC (AFlow), Transbond ® Supreme LV (LVFlow), Opallis (OPFlow), and Filtek Z350XT were exposed to coffee (CF), red wine (RW), cola drink (CO), or artificial saliva (AS), followed by daily bleaching with 10% hydrogen peroxide. Color changes (ΔE 00) and Whiteness Index for Dentistry changes (ΔWI D) were analyzed by spectrophotometry (n = 10/group) at baseline (T 0), after staining (T 1), and after bleaching (T 2). Degree of conversion (DC) and maximum polymerization rate (Rp max) were assessed by FT-IR. Data were analyzed using generalized linear models (α = 5%). Results At T 1 –T 0, CF and RW produced greater staining than CO and AS, while OPFlow showed the lowest color changes, particularly after CF exposure (p < 0.05). At T 2 –T 1, the whitening response depended on the previous staining solution and composite, with greater changes after RW exposure. At T 2 –T 0, CF and RW resulted in the greatest residual color changes, whereas OPFlow showed the lowest residual staining, particularly under CF and RW (p < 0.05). DC differed significantly among the tested composites (p < 0.05), and OPFlow presented the highest RPmax (p < 0.05). Conclusions Staining and whitening responses depended on resin composite and staining solution. OPFlow, which is not specifically directed for attachment fabrication, generally showed lower residual staining after bleaching. In addition, polymerization characteristics differed among materials. Clinical Significance Resin composites specifically formulated and indicated for clear aligner attachment fabrication showed greater susceptibility to staining than a general-purpose flowable composite. Whitening procedures reduced discoloration but did not fully reverse staining in the attachment-specific materials.

Authors

Institutions

Publication Details

Journal
Clinical Oral Investigations
Published
2026-11-25
DOI
https://doi.org/10.1007/s00784-026-07301-z
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Resin composites for clear aligner attachments: staining resistance, whitening response, and degree of conversion

Bruna Marin Fronza, Michelle Sendyk, Matheus Kury, Rebeca J.G. Rodrigues et al.
3 links
Clinical Oral Investigations
Dental materials and restorations
article

Resin composites for clear aligner attachments: staining resistance, whitening response, and degree of conversion

Bruna Marin Fronza, Michelle Sendyk, Matheus Kury, Rebeca J.G. Rodrigues, Giulia G. Pizzanelli, Adriano F. Lima, Vinicius H. Hutemma
article en

Abstract

Objectives This study evaluated the staining resistance and whitening response of resin composites indicated for clear aligner attachment fabrication compared with restorative composites and characterized their polymerization kinetics. Methods Discs of Aligner Flow LC (AFlow), Transbond ® Supreme LV (LVFlow), Opallis (OPFlow), and Filtek Z350XT were exposed to coffee (CF), red wine (RW), cola drink (CO), or artificial saliva (AS), followed by daily bleaching with 10% hydrogen peroxide. Color changes (ΔE 00) and Whiteness Index for Dentistry changes (ΔWI D) were analyzed by spectrophotometry (n = 10/group) at baseline (T 0), after staining (T 1), and after bleaching (T 2). Degree of conversion (DC) and maximum polymerization rate (Rp max) were assessed by FT-IR. Data were analyzed using generalized linear models (α = 5%). Results At T 1 –T 0, CF and RW produced greater staining than CO and AS, while OPFlow showed the lowest color changes, particularly after CF exposure (p < 0.05). At T 2 –T 1, the whitening response depended on the previous staining solution and composite, with greater changes after RW exposure. At T 2 –T 0, CF and RW resulted in the greatest residual color changes, whereas OPFlow showed the lowest residual staining, particularly under CF and RW (p < 0.05). DC differed significantly among the tested composites (p < 0.05), and OPFlow presented the highest RPmax (p < 0.05). Conclusions Staining and whitening responses depended on resin composite and staining solution. OPFlow, which is not specifically directed for attachment fabrication, generally showed lower residual staining after bleaching. In addition, polymerization characteristics differed among materials. Clinical Significance Resin composites specifically formulated and indicated for clear aligner attachment fabrication showed greater susceptibility to staining than a general-purpose flowable composite. Whitening procedures reduced discoloration but did not fully reverse staining in the attachment-specific materials.

Clinical Oral InvestigationsVol. 30(12)
Hospital Israelita Albert Einstein (BR), Universidade Paulista (BR)
Fundação de Amparo à Pesquisa do Estado de São Paulo, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Good health and well-being
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon