Topological Influence on the Flexural Mechanics of Additively Manufactured Sandwich Structures with Fiber-Reinforced Polyamide and Cellular Thermoplastic Polyurethane

The core architecture and face–core load transfer govern the bending response of additively manufactured sandwich structures. This study examines carbon-fiber-reinforced polyamide (PA-CF) and glass-fiber-reinforced polyamide (PA-GF) faces combined with thermoplastic polyurethane (TPU) cores in 22 configurations. Grid, Cross 3D, Honeycomb, Line and Gyroid cores were evaluated at 20% and 40% nominal infills, with solid-core controls. Beams measuring 100 × 20 × 10 mm were loaded for four-point bending over an 80 mm support span and a 40 mm loading span. Total force and crosshead displacement were used to determine the initial structural stiffness, apparent modulus, operational offset yield, maximum force and work accumulated to maximum force. Increasing the patterned infill from 20% to 40% increased the descriptive mean stiffness across the five topologies by 50.1% for PA-CF and 49.9% for PA-GF. PA-CF Grid at 40% infill provided the highest patterned stiffness and maximum force at 173.2 N/mm and 837.0 N. PA-GF Line at 40% infill gave the greatest patterned work to maximum force, 8.30 J, closely followed by PA-CF Gyroid at 8.21 J. PA-GF Grid illustrated the competing effects of reinforcement: maximum force increased by 50.8%, while displacement at the maximum force and prepeak work decreased by 53.4% and 45.9%. The PA-CF solid control reached 1615.6 N and 18.80 J. The contribution is the joint comparison of these competing design responses across the same material–topology–infill matrix. An equivalent-core finite-element model with linear-elastic materials and large-deflection kinematics underestimated displacement by 45.28–88.03%, showing the limitations of the assumed infill-scaled homogeneous core. The findings support the joint selection of face material, topology, and infill according to stiffness, load capacity, and deformation requirements; prepeak work is a structural test-system quantity rather than fracture energy.

Authors

Institutions

Publication Details

Journal
Polymers
Published
2026-11-25
DOI
https://doi.org/10.3390/polym18232968
Primary Topic
Cellular and Composite Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Topological Influence on the Flexural Mechanics of Additively Manufactured Sandwich Structures with Fiber-Reinforced Polyamide and Cellular Thermoplastic Polyurethane

Amged Elhassan, Waleed Khalil Ahmed, Hemant Mittal, Amro Abdelsalam et al.
3 links
Polymers
Cellular and Composite Structures
article

Topological Influence on the Flexural Mechanics of Additively Manufactured Sandwich Structures with Fiber-Reinforced Polyamide and Cellular Thermoplastic Polyurethane

Amged Elhassan, Waleed Khalil Ahmed, Hemant Mittal, Amro Abdelsalam, Ali Mohamed, Hamiyar Ahmed
article en

Abstract

The core architecture and face–core load transfer govern the bending response of additively manufactured sandwich structures. This study examines carbon-fiber-reinforced polyamide (PA-CF) and glass-fiber-reinforced polyamide (PA-GF) faces combined with thermoplastic polyurethane (TPU) cores in 22 configurations. Grid, Cross 3D, Honeycomb, Line and Gyroid cores were evaluated at 20% and 40% nominal infills, with solid-core controls. Beams measuring 100 × 20 × 10 mm were loaded for four-point bending over an 80 mm support span and a 40 mm loading span. Total force and crosshead displacement were used to determine the initial structural stiffness, apparent modulus, operational offset yield, maximum force and work accumulated to maximum force. Increasing the patterned infill from 20% to 40% increased the descriptive mean stiffness across the five topologies by 50.1% for PA-CF and 49.9% for PA-GF. PA-CF Grid at 40% infill provided the highest patterned stiffness and maximum force at 173.2 N/mm and 837.0 N. PA-GF Line at 40% infill gave the greatest patterned work to maximum force, 8.30 J, closely followed by PA-CF Gyroid at 8.21 J. PA-GF Grid illustrated the competing effects of reinforcement: maximum force increased by 50.8%, while displacement at the maximum force and prepeak work decreased by 53.4% and 45.9%. The PA-CF solid control reached 1615.6 N and 18.80 J. The contribution is the joint comparison of these competing design responses across the same material–topology–infill matrix. An equivalent-core finite-element model with linear-elastic materials and large-deflection kinematics underestimated displacement by 45.28–88.03%, showing the limitations of the assumed infill-scaled homogeneous core. The findings support the joint selection of face material, topology, and infill according to stiffness, load capacity, and deformation requirements; prepeak work is a structural test-system quantity rather than fracture energy.

PolymersVol. 18(23)
Dubai Health Authority (AE), United Arab Emirates University (AE), Dubai Electricity and Water Authority (AE)
Industry, innovation and infrastructure
Cellular and Composite Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon