Epileptic seizure or implantable cardioverter defibrillator shock? A case report highlighting nursing judgement in differential diagnosis
Background: Implantable cardioverter defibrillators have become central to the management of patients at risk of life-threatening ventricular arrhythmias. Although these devices improve survival, implantable cardioverter defibrillator-related events may sometimes present with seizure-like features, creating diagnostic uncertainty in clinical practice. In such situations, bedside nursing observation and clinical judgement may contribute to recognising the underlying cause. Case presentation: A 25-year-old man with dilated cardiomyopathy and a single-chamber ventricular implantable cardioverter defibrillator implanted in 2023 was admitted with acute pancreatitis complicated by infection. His body mass index was 51.9 kg/m 2. During his 82-day hospital stay, he experienced recurrent brief nocturnal seizure-like episodes characterised by limb stiffness and urinary incontinence. Neurological investigations did not support a diagnosis of epilepsy, yet the episodes continued. On Day 26, following another brief episode, the nurse assessed the patient at the bedside. While assessing his responsiveness and touching his arm, a further event occurred, during which the nurse perceived a brief electrical sensation through physical contact. This unexpected observation prompted immediate electrocardiogram (ECG) monitoring. During a subsequent event, ventricular tachycardia was documented on ECG, followed by abrupt termination of the arrhythmia. The patient was transferred to the intensive care unit for further cardiac management. Following medical treatment, no further seizure-like episodes were observed during the remainder of the hospital stay, and catheter ablation, which had initially been considered, was not required. Nursing interventions: Close bedside observation, timely recognition of an atypical clinical cue, and rapid escalation prompted cardiac reassessment and contributed to the identification of ventricular tachycardia. Subsequent nursing care focused on rhythm and clinical monitoring, symptom awareness, and patient and family education regarding implantable cardioverter defibrillator function and follow-up. Conclusions: This case illustrates how attentive bedside nursing assessment can inform clinical reasoning when neurological and cardiac symptoms overlap. Recognition of an unexpected clinical cue prompted cardiac reassessment, which led to ECG documentation of ventricular tachycardia. The case highlights the importance of timely nursing observation and escalation for patients with implantable cardiac devices presenting with seizure-like symptoms.
Authors
- Gülfigar Gülkaya (ORCID: https://orcid.org/0000-0003-4092-9087)
Institutions
- Bilkent University (TR)
- Başkent University Hospital (TR)
- Ankara Bilkent City Hospital (TR)
Publication Details
- Journal
- British Journal of Cardiac Nursing
- Published
- 2026-11-25
- DOI
- https://doi.org/10.12968/bjca.2026.0002
- Primary Topic
- Cardiac pacing and defibrillation studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00