IMPROVING THE TECHNICAL CONDITION INDEX METHOD FOR PRIORITISING THE RECONSTRUCTION OF A TRUNK WATER MAIN
The paper proposes an improved technical condition index (TCI) for ranking the sections of a single-line trunk water main by reconstruction priority, adapting V.A. Orlov's rating-point evaluation of destabilising factors. The index aggregates six normalised factors with weights obtained by expert pairwise comparison (Kendall's W = 0.71). For ten sections of the trunk main supplying Andijan (Uzbekistan), two sections fell into category III and eight into category IV (pre-failure). Of 179 defects recorded in 2016–2025, 31.8 % occurred in June–August. Failure-related losses were 348 thousand m³ over ten years, while hidden leakage is about 565 thousand m³ per year. A three-stage reconstruction sequence is substantiated.
Authors
- Salimjon Azamdjanovich Rahmonqulov
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-25
- DOI
- https://doi.org/10.5281/zenodo.24530977
- Primary Topic
- Water Systems and Optimization
- Type
- article
- Field-Weighted Citation Impact
- 0.00