Development and External Validation of a First‐Trimester Prediction Model for Fetal Growth Restriction Using Fully Automated Placental Ultrasound: A Prospective Multicentre Observational Study

OBJECTIVE: To develop and externally validate a first-trimester model for fetal growth restriction (FGR) using established risk factors alongside novel placental biomarkers. DESIGN: Two prospective cohort studies: one for model development and one for geographically and temporally distinct external validation. SETTING: A specialist fetal medicine centre (London) and a routine NHS ultrasound department (Oxford), UK. POPULATION: weeks of gestation. METHODS: Alongside routine antenatal care, an additional first trimester three-dimensional placental scan with power Doppler was performed. The OxNNet Toolkit Placenta automatically derived placental volume and perfusion biomarkers (single vessel fractional moving blood volume), combined with established risk factors in a competing-risks (Fine-Gray) model. Development-cohort coefficients were applied unchanged on external validation. MAIN OUTCOME MEASURES: Composite FGR (birthweight < 3rd centile, < 10th centile with abnormal fetal Doppler or < 10th centile with neonatal unit admission); discrimination (area under the curve, AUC) and detection rate at matched false-positive rates. RESULTS: Of 6196 pregnancies (3083 [49.8%] nulliparous), 383 (6.2%) developed composite FGR. Placental volume was among the strongest predictors, second only to ethnicity. On external validation the AUC was 0.75 (95% CI 0.71-0.79). At the 34% false-positive rate of the existing UK risk-assessment approach, the model detected 70.1% (95% CI 62.1-78.6) of composite FGR cases, compared with 48% detection by the existing approach in the OxPLUS cohort. Performance was maintained in nulliparous women (AUC 0.71 [0.66-0.77]). CONCLUSIONS: Novel placental biomarkers contribute significantly to predictive performance, and the model performed well on internal and external validation and outperformed the existing UK risk-assessment approach. Performance was maintained in nulliparous women, who are particularly disadvantaged by current FGR risk prediction. The model could either substantially improve detection at a similar surveillance burden or reduce surveillance referrals while maintaining improved detection; prospective implementation and health-economic evaluation will determine the optimal operating threshold.

Authors

Institutions

Publication Details

Journal
BJOG An International Journal of Obstetrics & Gynaecology
Published
2026-11-25
DOI
https://doi.org/10.1111/1471-0528.70383
Primary Topic
Pregnancy and preeclampsia studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development and External Validation of a First‐Trimester Prediction Model for Fetal Growth Restriction Using Fully Automated Placental Ultrasound: A Prospective Multicentre Observational Study

Sam Mathewlynn, Argyro Syngelaki, Yi Yin, Sally Collins et al.
2 links
BJOG An International Journal of Obstetrics & Gynaecology
Pregnancy and preeclampsia studies
article

Development and External Validation of a First‐Trimester Prediction Model for Fetal Growth Restriction Using Fully Automated Placental Ultrasound: A Prospective Multicentre Observational Study

Sam Mathewlynn, Argyro Syngelaki, Yi Yin, Sally Collins, Stephen Gerry, Theophilus Adu–Bredu, Mohammadreza Soltaninejad, Kypros H. Nicolaides, A. Galán Contreras, L Starck, E.‐M. Woess, May Swinburne, Sara Bigiotti, K. Shipp
article en

Abstract

OBJECTIVE: To develop and externally validate a first-trimester model for fetal growth restriction (FGR) using established risk factors alongside novel placental biomarkers. DESIGN: Two prospective cohort studies: one for model development and one for geographically and temporally distinct external validation. SETTING: A specialist fetal medicine centre (London) and a routine NHS ultrasound department (Oxford), UK. POPULATION: weeks of gestation. METHODS: Alongside routine antenatal care, an additional first trimester three-dimensional placental scan with power Doppler was performed. The OxNNet Toolkit Placenta automatically derived placental volume and perfusion biomarkers (single vessel fractional moving blood volume), combined with established risk factors in a competing-risks (Fine-Gray) model. Development-cohort coefficients were applied unchanged on external validation. MAIN OUTCOME MEASURES: Composite FGR (birthweight < 3rd centile, < 10th centile with abnormal fetal Doppler or < 10th centile with neonatal unit admission); discrimination (area under the curve, AUC) and detection rate at matched false-positive rates. RESULTS: Of 6196 pregnancies (3083 [49.8%] nulliparous), 383 (6.2%) developed composite FGR. Placental volume was among the strongest predictors, second only to ethnicity. On external validation the AUC was 0.75 (95% CI 0.71-0.79). At the 34% false-positive rate of the existing UK risk-assessment approach, the model detected 70.1% (95% CI 62.1-78.6) of composite FGR cases, compared with 48% detection by the existing approach in the OxPLUS cohort. Performance was maintained in nulliparous women (AUC 0.71 [0.66-0.77]). CONCLUSIONS: Novel placental biomarkers contribute significantly to predictive performance, and the model performed well on internal and external validation and outperformed the existing UK risk-assessment approach. Performance was maintained in nulliparous women, who are particularly disadvantaged by current FGR risk prediction. The model could either substantially improve detection at a similar surveillance burden or reduce surveillance referrals while maintaining improved detection; prospective implementation and health-economic evaluation will determine the optimal operating threshold.

BJOG An International Journal of Obstetrics & Gynaecology
University of Bristol (GB), University of Oxford (GB), Oxford University Hospitals NHS Trust (GB), King's College Hospital (GB)
National Institute for Health and Care Research, Sir Jules Thorn Charitable Trust
Good health and well-being
Pregnancy and preeclampsia studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon