Heat Reduction in Erbium-Doped Microresonator

We investigate anti-Stokes fluorescence in a 106-micrometer-diameter silica whispering-gallery-mode microresonator coated with erbium-doped sol-gel, assessing its potential for reduced optical heating. Near-infrared fluorescence spectra acquired under pulsed excitation near 1.55 micrometers exhibit a mean emitted photon energy above the pump photon energy. Measurements over a temperature range of 25 to 62 degrees Celsius show that the mean fluorescence photon energy increases with externally controlled temperature. The measured pump-wavelength dependence is consistent with an absorption-weighted spectral model, which predicts an optimum near 1562.65 nm for the investigated spectral figure of merit. Resonance-dependent emission patterns further motivate a dual-frequency pumping scheme using two higher-order whispering-gallery modes. Calculated time-averaged field profiles indicate that complementary modal distributions can provide more uniform excitation near the equator. These results characterize spectral conditions relevant to fluorescence-based heat reduction and suggest a route toward improved spatial pump coverage. Demonstrating net optical refrigeration requires additional measurements of absorbed pump power and an independent thermal readout.

Authors

Publication Details

Journal
arXiv
Published
2026-11-24
DOI
https://doi.org/10.48550/arxiv.2611.32754
Primary Topic
Photonic and Optical Devices
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Heat Reduction in Erbium-Doped Microresonator

Pavel Sidorenko, Bar Favelukis, Raz Gvishi, Nitzan Shani et al.
arXiv
Photonic and Optical Devices
preprint

Heat Reduction in Erbium-Doped Microresonator

Pavel Sidorenko, Bar Favelukis, Raz Gvishi, Nitzan Shani, Tal Carmon, Menachem Guttmann
preprint en

Abstract

We investigate anti-Stokes fluorescence in a 106-micrometer-diameter silica whispering-gallery-mode microresonator coated with erbium-doped sol-gel, assessing its potential for reduced optical heating. Near-infrared fluorescence spectra acquired under pulsed excitation near 1.55 micrometers exhibit a mean emitted photon energy above the pump photon energy. Measurements over a temperature range of 25 to 62 degrees Celsius show that the mean fluorescence photon energy increases with externally controlled temperature. The measured pump-wavelength dependence is consistent with an absorption-weighted spectral model, which predicts an optimum near 1562.65 nm for the investigated spectral figure of merit. Resonance-dependent emission patterns further motivate a dual-frequency pumping scheme using two higher-order whispering-gallery modes. Calculated time-averaged field profiles indicate that complementary modal distributions can provide more uniform excitation near the equator. These results characterize spectral conditions relevant to fluorescence-based heat reduction and suggest a route toward improved spatial pump coverage. Demonstrating net optical refrigeration requires additional measurements of absorbed pump power and an independent thermal readout.

arXiv
Photonic and Optical Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon