Propagation-based seizure detection for wearable EEG using planar and spatial EEG modeling

Introduction: This study proposes a propagation-based seizure detection framework for wearable-oriented electroencephalography (EEG) monitoring and investigates its performance across different electrode configurations and independent EEG datasets. Materials and methods: Seizure propagation was modeled using two-dimensional (2D) and three-dimensional (3D) representations for planar and spatial electrode configurations, respectively. The framework was evaluated using leave-one-subject-out cross-validation on the Temple University Hospital EEG Seizure Corpus (TUSZ) and further assessed retrospectively on the independent Children’s Hospital Boston–Massachusetts Institute of Technology (CHB-MIT) scalp EEG database using a common four-channel bipolar montage with limited operating-threshold calibration. Cross-dataset performance was examined using a reduced feature set and temporal post-processing, with these configurations selected based on the CHB-MIT evaluation results. Results: The proposed framework outperformed conventional feature-based seizure detection while using fewer electrodes. For spatial electrode configurations, the complete 3D propagation representation significantly improved focal seizure sensitivity compared with the 2D representation under matched-electrode conditions. When adapted to a wearable-oriented four-channel bipolar montage, the framework achieved sensitivities of 92.34%, 83.94%, and 92.01% with area under the receiver operating characteristic curve (AUC) of 0.975, 0.959, and 0.962 for generalized, focal, and combined seizure detection, respectively. Retrospective cross-dataset evaluation demonstrated the potential for transfer of the TUSZ-trained classifier to CHB-MIT with limited threshold calibration, while feature refinement and temporal post-processing improved the observed sensitivity–false-alarm trade-off. Conclusions: The findings support the discriminative value of geometry-aware propagation representations across planar and spatial electrode configurations and demonstrate promising seizure detection performance using a wearable-oriented four-channel bipolar montage. The retrospective cross-dataset findings further suggest potential transferability, although independent validation of the selected feature and temporal-correction configurations remains necessary. Future prospective evaluation using wearable EEG hardware is needed to establish practical monitoring performance.

Authors

Institutions

Publication Details

Journal
Academia Neuroscience and Brain Research
Published
2026-11-25
DOI
https://doi.org/10.20935/acadneurosci8659
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Propagation-based seizure detection for wearable EEG using planar and spatial EEG modeling

Dhanushka Wijesinghe, Ivan T. Lima
1 links
Academia Neuroscience and Brain Research
EEG and Brain-Computer Interfaces
article

Propagation-based seizure detection for wearable EEG using planar and spatial EEG modeling

Dhanushka Wijesinghe, Ivan T. Lima
article en

Abstract

Introduction: This study proposes a propagation-based seizure detection framework for wearable-oriented electroencephalography (EEG) monitoring and investigates its performance across different electrode configurations and independent EEG datasets. Materials and methods: Seizure propagation was modeled using two-dimensional (2D) and three-dimensional (3D) representations for planar and spatial electrode configurations, respectively. The framework was evaluated using leave-one-subject-out cross-validation on the Temple University Hospital EEG Seizure Corpus (TUSZ) and further assessed retrospectively on the independent Children’s Hospital Boston–Massachusetts Institute of Technology (CHB-MIT) scalp EEG database using a common four-channel bipolar montage with limited operating-threshold calibration. Cross-dataset performance was examined using a reduced feature set and temporal post-processing, with these configurations selected based on the CHB-MIT evaluation results. Results: The proposed framework outperformed conventional feature-based seizure detection while using fewer electrodes. For spatial electrode configurations, the complete 3D propagation representation significantly improved focal seizure sensitivity compared with the 2D representation under matched-electrode conditions. When adapted to a wearable-oriented four-channel bipolar montage, the framework achieved sensitivities of 92.34%, 83.94%, and 92.01% with area under the receiver operating characteristic curve (AUC) of 0.975, 0.959, and 0.962 for generalized, focal, and combined seizure detection, respectively. Retrospective cross-dataset evaluation demonstrated the potential for transfer of the TUSZ-trained classifier to CHB-MIT with limited threshold calibration, while feature refinement and temporal post-processing improved the observed sensitivity–false-alarm trade-off. Conclusions: The findings support the discriminative value of geometry-aware propagation representations across planar and spatial electrode configurations and demonstrate promising seizure detection performance using a wearable-oriented four-channel bipolar montage. The retrospective cross-dataset findings further suggest potential transferability, although independent validation of the selected feature and temporal-correction configurations remains necessary. Future prospective evaluation using wearable EEG hardware is needed to establish practical monitoring performance.

Academia Neuroscience and Brain ResearchVol. 2(4)
North Dakota State University (US)
Good health and well-being
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon