Chemistry decides the calibration unit: five direct and one water-mediated interaction class

Typed protein–ligand contact models predict which interactions form, but they return point probabilities, not a statement of how often the true contact is included. We formulate per-atom, multi-label interaction sets for five direct contact classes (H-bond, hydrophobic, π, salt, halogen) and add water as a sixth, water-mediated class. Using cross-conformal calibration and conformal risk control on 750 crystal complexes across 29 targets, we show that the calibration unit is a chemical decision rather than a statistical default. At the 90% nominal level a chemistry-aware nonconformity score reduces set size by 7.9% (target-held-out) and 13.2% (scaffold-held-out), changing coverage by only +0.6/−0.6 percentage points. Per-type risk control attains false-negative rates of 0.096/0.079 at a 10% target, but only for classes with enough calibration positives: salt has 42 positives and is not estimable, while π is under-covered by a global threshold. Water is abundant (1,258 positives; 5.4% of ligand heavy atoms; 72% of complexes) and target-specific. A global threshold on the probability score leaves water at 0.905/0.937/0.931/0.853 coverage on target/scaffold/temporal/strict splits, but the original chemistry-aware score is water-blind by construction and drops to 0.735/0.751/0.750/0.635. Making the partner term water-aware recovers only 0.848/0.877/0.886/0.787, while per-type control gives 0.923/0.937/0.928/0.857. Per-type control is therefore not a universal winner: it fixes π and water, can lower halogen, and cannot estimate salt. The calibration unit should follow the chemistry of the class, not an aggregate coverage target.

Authors

Institutions

Publication Details

Journal
ChemRxiv
Published
2026-11-24
DOI
https://doi.org/10.26434/chemrxiv.15012735/v1
Primary Topic
Computational Drug Discovery Methods
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Chemistry decides the calibration unit: five direct and one water-mediated interaction class

Xiongjie Xiao, Yi Huang, Bin Jiang, Xu Zhang et al.
ChemRxiv
Computational Drug Discovery Methods
preprint

Chemistry decides the calibration unit: five direct and one water-mediated interaction class

Xiongjie Xiao, Yi Huang, Bin Jiang, Xu Zhang, Maili Liu
preprint en

Abstract

Typed protein–ligand contact models predict which interactions form, but they return point probabilities, not a statement of how often the true contact is included. We formulate per-atom, multi-label interaction sets for five direct contact classes (H-bond, hydrophobic, π, salt, halogen) and add water as a sixth, water-mediated class. Using cross-conformal calibration and conformal risk control on 750 crystal complexes across 29 targets, we show that the calibration unit is a chemical decision rather than a statistical default. At the 90% nominal level a chemistry-aware nonconformity score reduces set size by 7.9% (target-held-out) and 13.2% (scaffold-held-out), changing coverage by only +0.6/−0.6 percentage points. Per-type risk control attains false-negative rates of 0.096/0.079 at a 10% target, but only for classes with enough calibration positives: salt has 42 positives and is not estimable, while π is under-covered by a global threshold. Water is abundant (1,258 positives; 5.4% of ligand heavy atoms; 72% of complexes) and target-specific. A global threshold on the probability score leaves water at 0.905/0.937/0.931/0.853 coverage on target/scaffold/temporal/strict splits, but the original chemistry-aware score is water-blind by construction and drops to 0.735/0.751/0.750/0.635. Making the partner term water-aware recovers only 0.848/0.877/0.886/0.787, while per-type control gives 0.923/0.937/0.928/0.857. Per-type control is therefore not a universal winner: it fixes π and water, can lower halogen, and cannot estimate salt. The calibration unit should follow the chemistry of the class, not an aggregate coverage target.

ChemRxiv
Chinese Academy of Sciences (CN), Wuhan Institute of Physics and Mathematics (CN), Wuhan National Laboratory for Optoelectronics (CN), University of Chinese Academy of Sciences (CN), Optics Valley Laboratory (CN), Innovation Academy for Precision Measurement Science and Technology, CAS (CN), Huazhong University of Science and Technology (CN)
Computational Drug Discovery Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon