Consistency of diagnostic-to-procedural lesion conspicuity in contrast-enhanced mammography-guided biopsy
OBJECTIVES: To evaluate whether lesion conspicuity remains consistent between diagnostic and biopsy acquisitions in recombined-only lesions undergoing contrast-enhanced mammography (CEM)-guided biopsy, and to identify determinants of reduced procedural conspicuity. MATERIALS AND METHODS: This retrospective single-centre study included 169 consecutive recombined-only lesions undergoing CEM-guided biopsy between October 2019 and September 2025. Lesion conspicuity (LC) was assessed on diagnostic and projection-matched stereotactic scout recombined images using a three-level ordinal scale (low, moderate, or high). Reduced procedural conspicuity was defined as a decrease in LC category. Continuous perceptual variation was assessed using a visual analogue scale (VAS). Associations between ordinal LC change (ΔLC) and median VAS were evaluated using Spearman correlation. Multivariable logistic regression using Firth's penalized likelihood method was performed to identify predictors of reduced conspicuity. RESULTS: Procedural LC was maintained or increased in 136/169 lesions (80.5%), whereas reduced conspicuity occurred in 33/169 lesions (19.5%). The same diagnostic and procedural LC category was observed in 111/169 lesions (65.7%). ΔLC correlated with median VAS (Spearman ρ = 0.665; p < 0.001). In multivariable analysis, non-mass enhancement morphology (adjusted OR 5.10, 95% CI: 1.94-14.06; p < 0.001) was independently associated with reduced conspicuity, whereas marked background parenchymal enhancement demonstrated a positive but statistically non-significant trend (adjusted OR 3.49, 95% CI: 0.97-12.55; p = 0.055). Technical variables were not independently associated. CONCLUSIONS: LC remained largely consistent between diagnostic and procedural acquisitions in most lesions undergoing CEM-guided biopsy. Reduced conspicuity was primarily associated with non-mass enhancement morphology rather than acquisition-related factors. KEY POINTS: Question Does LC remain consistent between diagnostic and biopsy acquisitions during CEM-guided biopsy, and which factors are associated with reduced procedural conspicuity? Findings LC remained stable or increased in most lesions undergoing CEM-guided biopsy, with reduced conspicuity primarily associated with non-mass enhancement morphology. Clinical relevance LC is generally preserved at the CEM-guided biopsy scout acquisition, supporting consistent procedural visualisation of recombined-only lesions.
Authors
- Elisenda Vall
- Rodrigo Correia de Alcântara (ORCID: https://orcid.org/0000-0003-4365-5640)
- José María Maiques
- Natalia Arenas
- Xavier Castells
Institutions
- Universitat Autònoma de Barcelona (ES)
- Universitat Pompeu Fabra (ES)
- Instituto de Salud Carlos III (ES)
- Hospital Del Mar (ES)
- Parc de Salut (ES)
- Hospital del Mar Research Institute (ES)
Publication Details
- Journal
- European Radiology
- Published
- 2026-11-25
- DOI
- https://doi.org/10.1007/s00330-026-13078-2
- Primary Topic
- Digital Radiography and Breast Imaging
- Type
- article
- Field-Weighted Citation Impact
- 0.00