Design, Economics Evaluation, and Simulation of Proposed Independent Solar Photovoltaics System for the Electrification of Itunta Village

Access to reliable electricity remains a major challenge in rural Nigeria, where grid extension and diesel generation are costly and uncertain. This study develops a field-informed techno-economic and long-term reliability framework for a standalone photovoltaic mini-grid serving Itunta Village. The load assessment covered all 136 accessible households and community facilities, while solar-resource characterization used PVGIS data for 2005–2025. The baseline demand was 806.16 kWh/day, and the conservative design comprised 401 SunPower 435 W modules (174.32 kWp) and 896 lithium-ion battery units. The array produced an average daily yield of 890.41 kWh/day, with seasonal output decreasing to approximately 660 kWh/day in July. The scientific contribution is the integration of field-based load aggregation, stochastic resource variation, battery cost–reliability optimization, lifecycle costing, and 25-year adequacy projection within one reproducible case-study framework. A technical sensitivity screen showed that a 10% reduction in irradiance removes the average energy margin, while a 10% increase in load nearly exhausts it, demonstrating the importance of uncertainty-aware sizing. The optimized one-day-autonomy configuration reduced the battery bank to 598 units and the battery cost to approximately ₦344.45 million while maintaining 95.974% reliability and an LPSP of 0.040256. The simplified LCOE was ₦89.91/kWh, whereas the discounted lifecycle LCOE was ₦358.63/kWh and the corresponding net present cost was approximately ₦1.02 billion. Long-term simulation showed that reliability decreases from 91.82% in Year 1 to 54.26% in Year 25 under 2% annual load growth, with a substantially faster decline under 5% growth. The results indicate that the system is technically feasible for present demand but requires modular implementation, disciplined battery management, and planned mid-life expansion to remain reliable over its full service life.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-25
DOI
https://doi.org/10.21203/rs.3.rs-11420513/v1
Primary Topic
Hybrid Renewable Energy Systems
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Design, Economics Evaluation, and Simulation of Proposed Independent Solar Photovoltaics System for the Electrification of Itunta Village

Igwe Johnson Eze, Emmanuel Ebube Eze, Anyaele Jude Uwakwe
2 links
Research Square
Hybrid Renewable Energy Systems
preprint

Design, Economics Evaluation, and Simulation of Proposed Independent Solar Photovoltaics System for the Electrification of Itunta Village

Igwe Johnson Eze, Emmanuel Ebube Eze, Anyaele Jude Uwakwe
preprint en

Abstract

Access to reliable electricity remains a major challenge in rural Nigeria, where grid extension and diesel generation are costly and uncertain. This study develops a field-informed techno-economic and long-term reliability framework for a standalone photovoltaic mini-grid serving Itunta Village. The load assessment covered all 136 accessible households and community facilities, while solar-resource characterization used PVGIS data for 2005–2025. The baseline demand was 806.16 kWh/day, and the conservative design comprised 401 SunPower 435 W modules (174.32 kWp) and 896 lithium-ion battery units. The array produced an average daily yield of 890.41 kWh/day, with seasonal output decreasing to approximately 660 kWh/day in July. The scientific contribution is the integration of field-based load aggregation, stochastic resource variation, battery cost–reliability optimization, lifecycle costing, and 25-year adequacy projection within one reproducible case-study framework. A technical sensitivity screen showed that a 10% reduction in irradiance removes the average energy margin, while a 10% increase in load nearly exhausts it, demonstrating the importance of uncertainty-aware sizing. The optimized one-day-autonomy configuration reduced the battery bank to 598 units and the battery cost to approximately ₦344.45 million while maintaining 95.974% reliability and an LPSP of 0.040256. The simplified LCOE was ₦89.91/kWh, whereas the discounted lifecycle LCOE was ₦358.63/kWh and the corresponding net present cost was approximately ₦1.02 billion. Long-term simulation showed that reliability decreases from 91.82% in Year 1 to 54.26% in Year 25 under 2% annual load growth, with a substantially faster decline under 5% growth. The results indicate that the system is technically feasible for present demand but requires modular implementation, disciplined battery management, and planned mid-life expansion to remain reliable over its full service life.

Research Square
Michael Okpara University of Agriculture (NG)
Affordable and clean energy, Industry, innovation and infrastructure, Climate action, No poverty
Hybrid Renewable Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.