FOCUS: A Frequency Offset Selection Framework for Accelerated CEST MRI Using Adaptive Subset‐Level Optimization

PURPOSE: To develop a redundancy-aware frequency offset selection framework for accelerated chemical exchange saturation transfer (CEST) MRI that reduces acquired saturation frequency offsets while preserving quantitative and classification performance. METHODS: FOCUS, a Frequency Offset selection framework for accelerated CEST MRI Using adaptive Subset-level optimization, was developed to account for inter-offset redundancy beyond individual offset importance. Frequency offset selection was formulated as subset-level optimization, in which candidate subsets were encoded as binary individuals and evaluated by final task performance. An artificial protozoa optimizer-based search scheme was used to explore the subset space, and a deep Q-network adaptively guided the search strategy. FOCUS was evaluated in numerical simulations, in vivo human skeletal muscle phosphocreatine quantification, and glioma molecular subtype classification, and compared with permutation importance analysis, random forest, and channel pruning. RESULTS: Under reduced frequency-offset sampling, FOCUS outperformed existing methods in both CEST quantification and glioma molecular subtype classification. For CEST quantification, FOCUS achieved the lowest root mean square error in simulations and in vivo skeletal muscle experiments, with the highest structural similarity index and peak signal-to-noise ratio in vivo. For glioma classification, FOCUS achieved the best overall performance in predicting isocitrate dehydrogenase mutation and O6-methylguanine-DNA methyltransferase promoter methylation status. CONCLUSION: FOCUS enables redundancy-aware frequency offset selection for accelerated CEST MRI, reducing acquired saturation frequency offsets while preserving quantitative accuracy and classification performance.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2026-11-24
DOI
https://doi.org/10.1002/mrm.70686
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

FOCUS: A Frequency Offset Selection Framework for Accelerated CEST MRI Using Adaptive Subset‐Level Optimization

Jianpan Huang, Xinran Chen, Lin Chen, Zhou Yang et al.
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
article

FOCUS: A Frequency Offset Selection Framework for Accelerated CEST MRI Using Adaptive Subset‐Level Optimization

Jianpan Huang, Xinran Chen, Lin Chen, Zhou Yang, Xinding Jiang, Gongkai Lai, Jinhui Wu, Zhekai Chen
article en

Abstract

PURPOSE: To develop a redundancy-aware frequency offset selection framework for accelerated chemical exchange saturation transfer (CEST) MRI that reduces acquired saturation frequency offsets while preserving quantitative and classification performance. METHODS: FOCUS, a Frequency Offset selection framework for accelerated CEST MRI Using adaptive Subset-level optimization, was developed to account for inter-offset redundancy beyond individual offset importance. Frequency offset selection was formulated as subset-level optimization, in which candidate subsets were encoded as binary individuals and evaluated by final task performance. An artificial protozoa optimizer-based search scheme was used to explore the subset space, and a deep Q-network adaptively guided the search strategy. FOCUS was evaluated in numerical simulations, in vivo human skeletal muscle phosphocreatine quantification, and glioma molecular subtype classification, and compared with permutation importance analysis, random forest, and channel pruning. RESULTS: Under reduced frequency-offset sampling, FOCUS outperformed existing methods in both CEST quantification and glioma molecular subtype classification. For CEST quantification, FOCUS achieved the lowest root mean square error in simulations and in vivo skeletal muscle experiments, with the highest structural similarity index and peak signal-to-noise ratio in vivo. For glioma classification, FOCUS achieved the best overall performance in predicting isocitrate dehydrogenase mutation and O6-methylguanine-DNA methyltransferase promoter methylation status. CONCLUSION: FOCUS enables redundancy-aware frequency offset selection for accelerated CEST MRI, reducing acquired saturation frequency offsets while preserving quantitative accuracy and classification performance.

Magnetic Resonance in Medicine
Xiamen University (CN), Chinese Academy of Sciences (CN), Shenzhen Institutes of Advanced Technology (CN), Xiamen University of Technology (CN), University of Hong Kong (HK)
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon