An integrated hydrogeophysical workflow for identifying buried lower-salinity groundwater targets in the Ebro coastal delta
Study region The Ebro Delta (NE Spain), a low-lying Mediterranean delta with intensive irrigated agriculture; the study site is an agricultural property at Sant Jaume d′Enveja where shallow groundwater is brackish and the deltaic succession is dominantly saline. Study focus We tested whether a compact hydrogeophysical workflow can identify a buried groundwater-bearing interval of comparatively low salinity within a saline deltaic succession and guide the completion of a production well. A 390 m pole–dipole electrical resistivity tomography (ERT) profile and two 75 × 75 m time-domain electromagnetic (TDEM) soundings were interpreted before drilling. A 61.7 m well, located 7 m from the ERT profile and 30 m from one TDEM sounding, was then logged (fluid electrical conductivity, temperature, natural gamma) and sampled at discrete depths (1, 40 and 55 m), and a pumping-test sample was measured. An Archie-type conversion was evaluated with a sensitivity analysis of the formation factor (F = 1.5–9). New hydrological insights for the region ERT and TDEM consistently resolve a thin surface unit, a highly conductive fine-grained unit (≈0.4–0.6 Ω m) between ≈ 5 and 25–34 m, an intermediate resistive gravel-dominated unit (≈7–20 Ω m) and a deeper conductor. In the screened part of the intermediate unit, groundwater electrical conductivity (EC) is 3.5–4.0 mS cm⁻¹ : brackish, but about one order of magnitude less saline than seawater, whereas EC rises to 9.1–12.4 mS cm⁻¹ at 55–61 m. A formation factor of ≈ 2 calibrated in clay-rich shallow sediments underestimated the pore-water EC of the gravel unit by a factor of ≈ 2.7; the sample-calibrated apparent F is ≈ 5.4. The lower boundary of the target is a salinity transition within the same gravels rather than an aquitard. Lower-salinity groundwater can therefore persist in semi-confined coarse units of the Ebro Delta, but its identification requires lithology-specific calibration with direct water samples, and its use requires screens ending above the salinity transition and EC-monitored abstraction to prevent upconing.
Authors
- Cristina Sáez Blázquez (ORCID: https://orcid.org/0000-0002-5333-0076)
- Miguel Ángel Maté‐González (ORCID: https://orcid.org/0000-0001-5721-346X)
- Ignacio Martín Nieto (ORCID: https://orcid.org/0000-0003-3984-7228)
- Diego González‐Aguilera (ORCID: https://orcid.org/0000-0002-8949-4216)
- Pedro Carrasco García (ORCID: https://orcid.org/0000-0002-0676-8278)
- Joaquim Enric Roset Piñol
- Javier Carrasco García
Institutions
- Universidad de Salamanca (ES)
- Universitat Rovira i Virgili (ES)
Publication Details
- Journal
- Journal of Hydrology Regional Studies
- Published
- 2026-11-25
- DOI
- https://doi.org/10.1016/j.ejrh.2026.104281
- Primary Topic
- Geophysical and Geoelectrical Methods
- Type
- article
- Field-Weighted Citation Impact
- 0.00