Mid‐Infrared Upconversion Spectroscopy at High Resolution and High Sensitivity

Mid‐infrared (MIR) spectroscopy with simultaneously high spectral resolution and high sensitivity is pivotal in physics, chemistry, and biology, yet its practical realization remains severely limited by the intrinsic noise of MIR photodetectors and the resolution constraints of conventional spectral‐dispersion architectures. Here, we demonstrate picometer‐resolution MIR upconversion spectroscopy by combining a tunable single‐frequency difference‐frequency generation source with external‐cavity‐enhanced nonlinear upconversion detection. A narrow‐linewidth MIR source enables ultra‐fine spectral interrogation, while a compact semi‐monolithic enhancement cavity enables low‐loss operation, enhanced stability, and an 84‐fold intracavity pump enhancement for efficient low‐noise frequency upconversion. Combined with an ultra‐sensitive silicon‐based single‐photon detector, the proposed system enables high‐resolution methane absorption spectroscopy with a spectral resolution of 0.002 (2.3 pm at 3.4 ) under incident MIR powers below 1 pW. The presented framework establishes a new route toward high‐performance MIR spectroscopy and opens new opportunities for molecular spectroscopy, trace analysis, and infrared sensing under photon‐starved conditions.

Authors

Institutions

Publication Details

Journal
Advanced Optical Materials
Published
2026-11-24
DOI
https://doi.org/10.1002/adom.72097
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Mid‐Infrared Upconversion Spectroscopy at High Resolution and High Sensitivity

Kun Huang, Yanan Li, Heping Zeng, Xu Wang et al.
Advanced Optical Materials
Spectroscopy and Laser Applications
article

Mid‐Infrared Upconversion Spectroscopy at High Resolution and High Sensitivity

Kun Huang, Yanan Li, Heping Zeng, Xu Wang, Wen Zhang, Yijing Li, Jianan Fang
article en

Abstract

Mid‐infrared (MIR) spectroscopy with simultaneously high spectral resolution and high sensitivity is pivotal in physics, chemistry, and biology, yet its practical realization remains severely limited by the intrinsic noise of MIR photodetectors and the resolution constraints of conventional spectral‐dispersion architectures. Here, we demonstrate picometer‐resolution MIR upconversion spectroscopy by combining a tunable single‐frequency difference‐frequency generation source with external‐cavity‐enhanced nonlinear upconversion detection. A narrow‐linewidth MIR source enables ultra‐fine spectral interrogation, while a compact semi‐monolithic enhancement cavity enables low‐loss operation, enhanced stability, and an 84‐fold intracavity pump enhancement for efficient low‐noise frequency upconversion. Combined with an ultra‐sensitive silicon‐based single‐photon detector, the proposed system enables high‐resolution methane absorption spectroscopy with a spectral resolution of 0.002 (2.3 pm at 3.4 ) under incident MIR powers below 1 pW. The presented framework establishes a new route toward high‐performance MIR spectroscopy and opens new opportunities for molecular spectroscopy, trace analysis, and infrared sensing under photon‐starved conditions.

Advanced Optical Materials
Shanxi University (CN), East China Normal University (CN)
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon