Active and Hybrid Mass Dampers for Seismic-Resilient Buildings: A Critical Review of Seismic Performance, Control Strategies, and Implementation Challenges

Active mass dampers (AMD) and hybrid mass dampers (HMD) modify the distribution of seismic demand in buildings through controlled auxiliary-mass motion. Their contribution to building protection depends on the feedback mechanism, actuator capacity, and interaction with the supporting structure. This critical review examines seismic performance, control strategies, and implementation across numerical studies, laboratory and hybrid experiments, full-scale tests, and installed systems. It relates the control mechanisms and validation conditions to tradeoffs among drift, floor acceleration, control force, and energy demand. Published experiments demonstrate force-tracking improvements and response attenuation. One full-scale campaign on paired reinforced-concrete soft-storey specimens provides direct damage-mitigation evidence for that configuration; installed observations establish event-specific operation rather than a general severe-earthquake protection level. Numerical comparisons reveal that displacement reduction can require greater actuator effort or increase acceleration, making the governing building-performance objective central to controller selection. Fractional-order feedback provides additional frequency-response flexibility, and sliding-mode control offers uncertainty compensation at the structural or actuator level. Combined and learning-assisted formulations may improve protection within force, travel, bandwidth, and power limits. The review relates these mechanisms to passive and semi-active baselines, installation requirements, component reliability, and operating-mode transitions through a qualitative synthesis. It does not provide a pooled effect estimate or a new benchmark simulation. Seismic resilience is the intended design objective; the reviewed AMD/HMD evidence does not establish recovery time or functional continuity. Research priorities are energy-efficient control at specified protection targets, coordinated response under multidirectional excitation, and integration of damage assessment with repair and functional-recovery metrics for seismic-resilient buildings.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-11-25
DOI
https://doi.org/10.3390/buildings16234725
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Active and Hybrid Mass Dampers for Seismic-Resilient Buildings: A Critical Review of Seismic Performance, Control Strategies, and Implementation Challenges

Oscar E. Camacho, Noel Pérez, Diego S. Benítez, Marco Herrera et al.
Buildings
Vibration Control and Rheological Fluids
article

Active and Hybrid Mass Dampers for Seismic-Resilient Buildings: A Critical Review of Seismic Performance, Control Strategies, and Implementation Challenges

Oscar E. Camacho, Noel Pérez, Diego S. Benítez, Marco Herrera, Pablo Torres‐Rodas, Luis Caiza, Fabricio Yèpez
article en

Abstract

Active mass dampers (AMD) and hybrid mass dampers (HMD) modify the distribution of seismic demand in buildings through controlled auxiliary-mass motion. Their contribution to building protection depends on the feedback mechanism, actuator capacity, and interaction with the supporting structure. This critical review examines seismic performance, control strategies, and implementation across numerical studies, laboratory and hybrid experiments, full-scale tests, and installed systems. It relates the control mechanisms and validation conditions to tradeoffs among drift, floor acceleration, control force, and energy demand. Published experiments demonstrate force-tracking improvements and response attenuation. One full-scale campaign on paired reinforced-concrete soft-storey specimens provides direct damage-mitigation evidence for that configuration; installed observations establish event-specific operation rather than a general severe-earthquake protection level. Numerical comparisons reveal that displacement reduction can require greater actuator effort or increase acceleration, making the governing building-performance objective central to controller selection. Fractional-order feedback provides additional frequency-response flexibility, and sliding-mode control offers uncertainty compensation at the structural or actuator level. Combined and learning-assisted formulations may improve protection within force, travel, bandwidth, and power limits. The review relates these mechanisms to passive and semi-active baselines, installation requirements, component reliability, and operating-mode transitions through a qualitative synthesis. It does not provide a pooled effect estimate or a new benchmark simulation. Seismic resilience is the intended design objective; the reviewed AMD/HMD evidence does not establish recovery time or functional continuity. Research priorities are energy-efficient control at specified protection targets, coordinated response under multidirectional excitation, and integration of damage assessment with repair and functional-recovery metrics for seismic-resilient buildings.

BuildingsVol. 16(23)
Universidad San Francisco de Quito (EC)
Universidad San Francisco de Quito
Sustainable cities and communities
Vibration Control and Rheological Fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.