PLC-Driven IoT Smart Lighting Systems: Reliable Communication for Urban Infrastructure

Smart cities require scalable Internet of Things (IoT) infrastructures for monitoring and controlling urban services. Public lighting is a key application because each luminaire may require dimming, electrical monitoring, and fault detection. Communicating with devices at every lighting point is challenging, while growth in monitored points can increase channel contention and infrastructure requirements in radio-based solutions. This work evaluates power line communication (PLC) over existing lighting conductors for individual dimming commands and electrical-current feedback, combining series-inductor conditioning with graph-based multihop forwarding. The architecture combines a cellular SmartPanel Gateway, SmartCap edge nodes, graph-based multihop routing, and a SmartCam using You Only Look Once (YOLO) object detection. Experiments evaluated approximately 20,000 complete dimming-and-current-feedback transactions per node and configuration using three logically independent PLC test systems connected concurrently to the same 200 m physical feeder. The evaluated configurations were direct PLC without filtering, direct PLC with 10 mH filtering, and filtered multihop PLC. An 18-device proof of concept was installed in Brasília, Brazil, where the PLC network topology was established through the complete commissioning workflow, including neighbor discovery, neighbor-information collection, graph generation, and route calculation, rather than through a manually predefined topology. The filtered direct configuration exhibited substantially higher successful transaction ratios at the more distant nodes under the tested conditions, while multihop forwarding further increased end-to-end reliability by completing transactions through intermediate nodes. Field measurements reproduced circuit operation and identified a current reduction associated with an extinguished luminaire, while the SmartCam identified traffic-activity periods for future automatic dimming. The results demonstrate feasibility, while large-scale routing performance, automatic route recovery under topology changes, cable-theft detection, and active dimming require further validation.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-11-25
DOI
https://doi.org/10.3390/s26237461
Primary Topic
Power Line Communications and Noise
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

PLC-Driven IoT Smart Lighting Systems: Reliable Communication for Urban Infrastructure

Leonardo de Mello Honório, Iago Z. Biundini, André Luís Marques Marcato, Vinícius Teixeira de Freitas da Conceição et al.
Sensors
Power Line Communications and Noise
article

PLC-Driven IoT Smart Lighting Systems: Reliable Communication for Urban Infrastructure

Leonardo de Mello Honório, Iago Z. Biundini, André Luís Marques Marcato, Vinícius Teixeira de Freitas da Conceição, Lucas Dias Hudson, Marcelo Giovane Alves
article en

Abstract

Smart cities require scalable Internet of Things (IoT) infrastructures for monitoring and controlling urban services. Public lighting is a key application because each luminaire may require dimming, electrical monitoring, and fault detection. Communicating with devices at every lighting point is challenging, while growth in monitored points can increase channel contention and infrastructure requirements in radio-based solutions. This work evaluates power line communication (PLC) over existing lighting conductors for individual dimming commands and electrical-current feedback, combining series-inductor conditioning with graph-based multihop forwarding. The architecture combines a cellular SmartPanel Gateway, SmartCap edge nodes, graph-based multihop routing, and a SmartCam using You Only Look Once (YOLO) object detection. Experiments evaluated approximately 20,000 complete dimming-and-current-feedback transactions per node and configuration using three logically independent PLC test systems connected concurrently to the same 200 m physical feeder. The evaluated configurations were direct PLC without filtering, direct PLC with 10 mH filtering, and filtered multihop PLC. An 18-device proof of concept was installed in Brasília, Brazil, where the PLC network topology was established through the complete commissioning workflow, including neighbor discovery, neighbor-information collection, graph generation, and route calculation, rather than through a manually predefined topology. The filtered direct configuration exhibited substantially higher successful transaction ratios at the more distant nodes under the tested conditions, while multihop forwarding further increased end-to-end reliability by completing transactions through intermediate nodes. Field measurements reproduced circuit operation and identified a current reduction associated with an extinguished luminaire, while the SmartCam identified traffic-activity periods for future automatic dimming. The results demonstrate feasibility, while large-scale routing performance, automatic route recovery under topology changes, cable-theft detection, and active dimming require further validation.

SensorsVol. 26(23)
Universidade Federal de Juiz de Fora (BR)
Agência Nacional de Energia Elétrica
Industry, innovation and infrastructure, Sustainable cities and communities
Power Line Communications and Noise
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon