Thermal Artifact After Pure Cut, Blend, and Hybrid Needle Excision of the Transformation Zone: A Retrospective Study

OBJECTIVE: To compare histopathologic thermal artifact and perioperative outcomes among pure cut, blend, and hybrid electrosurgical techniques for needle excision of the transformation zone. METHODS: In this retrospective comparative study, 119 women underwent needle excision of the transformation zone using pure cut mode at 50 W (n=40), blend mode at 50 W (n=40), or a hybrid technique consisting of pure cut mode at 50 W followed by cold scalpel completion of the terminal endocervical excision (n=39). Histopathologic thermal artifact at the endocervical, ectocervical, and stromal margins, together with the maximum depth of thermal artifact, was quantitatively assessed. Surgical margin status, specimen volume, operative time, blood loss, and other perioperative outcomes were also compared. RESULTS: Baseline demographic, clinical, and surgical characteristics were comparable among the 3 groups. Pure cut and blend modes produced similar degrees of thermal artifact and comparable perioperative outcomes. The hybrid technique significantly reduced endocervical thermal artifact (p<.001) and maximum thermal artifact depth (p=.02), while stromal thermal artifact was lower than with blend mode (p=.03). Ectocervical thermal artifact, surgical margin status, specimen volume, operative time, blood loss, and the need for additional hemostatic sutures did not differ significantly among the groups. CONCLUSIONS: Pure cut and blend modes yielded comparable histopathologic and perioperative outcomes. By selectively reducing endocervical thermal artifact without compromising surgical performance, the hybrid technique may be considered when optimal preservation of the endocervical margin is clinically important.

Authors

Institutions

Publication Details

Journal
Journal of Lower Genital Tract Disease
Published
2026-11-25
DOI
https://doi.org/10.1097/lgt.0000000000000998
Primary Topic
Cervical Cancer and HPV Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Thermal Artifact After Pure Cut, Blend, and Hybrid Needle Excision of the Transformation Zone: A Retrospective Study

Mehmet Ali Narin, Sevda Baş, Büşra Asena Torun, Aslıhan Alpaslan et al.
Journal of Lower Genital Tract Disease
Cervical Cancer and HPV Research
article

Thermal Artifact After Pure Cut, Blend, and Hybrid Needle Excision of the Transformation Zone: A Retrospective Study

Mehmet Ali Narin, Sevda Baş, Büşra Asena Torun, Aslıhan Alpaslan, Oğuz Uyar, Sevinç Püren Yücel Karakaya, Sibel Öncel
article en

Abstract

OBJECTIVE: To compare histopathologic thermal artifact and perioperative outcomes among pure cut, blend, and hybrid electrosurgical techniques for needle excision of the transformation zone. METHODS: In this retrospective comparative study, 119 women underwent needle excision of the transformation zone using pure cut mode at 50 W (n=40), blend mode at 50 W (n=40), or a hybrid technique consisting of pure cut mode at 50 W followed by cold scalpel completion of the terminal endocervical excision (n=39). Histopathologic thermal artifact at the endocervical, ectocervical, and stromal margins, together with the maximum depth of thermal artifact, was quantitatively assessed. Surgical margin status, specimen volume, operative time, blood loss, and other perioperative outcomes were also compared. RESULTS: Baseline demographic, clinical, and surgical characteristics were comparable among the 3 groups. Pure cut and blend modes produced similar degrees of thermal artifact and comparable perioperative outcomes. The hybrid technique significantly reduced endocervical thermal artifact (p<.001) and maximum thermal artifact depth (p=.02), while stromal thermal artifact was lower than with blend mode (p=.03). Ectocervical thermal artifact, surgical margin status, specimen volume, operative time, blood loss, and the need for additional hemostatic sutures did not differ significantly among the groups. CONCLUSIONS: Pure cut and blend modes yielded comparable histopathologic and perioperative outcomes. By selectively reducing endocervical thermal artifact without compromising surgical performance, the hybrid technique may be considered when optimal preservation of the endocervical margin is clinically important.

Journal of Lower Genital Tract Disease
Sağlık Bilimleri Üniversitesi (TR), Cukurova University (TR)
Good health and well-being
Cervical Cancer and HPV Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon