Feasibility of Community-Based Gait-Synchronised Functional Electrical Stimulation in Individuals with Transtibial Amputation and Chronic Pain: A Randomised Crossover Study

Background Chronic pain and altered gait commonly co-occur after transtibial amputation. Previous musculoskeletal modelling identified the residual knee extensors as a potential target for functional electrical stimulation (FES) to improve gait mechanics. Subsequent laboratory studies have demonstrated improved gait mechanics and suggested potential benefits for pain management. However, the feasibility and effects of prolonged FES use during daily life remain unclear. Methods Fourteen individuals with unilateral transtibial amputation and chronic pain completed a randomised crossover study comprising five weeks of daily quadriceps FES synchronised to the stance phase of gait and five weeks without FES, separated by a six-week washout. The primary outcome was feasibility, including retention, adherence, device use, safety, and participant feedback. Exploratory outcomes included knee kinematics assessed using wearable inertial measurement units and OpenSim-based inverse kinematics, and pain intensity and interference assessed using the Brief Pain Inventory (BPI-5 and BPI-9). FES was switched off during gait assessments to evaluate training rather than immediate orthotic effects. Scalar outcomes were analysed using baseline- and period-adjusted linear mixed-effects models. Results Retention was 100%, mean adherence was 94%, and no serious adverse events occurred. Device use averaged 3.52 ± 2.97 hours per active day. Mean frame-wise knee flexion symmetry index was significantly lower following FES than non-FES (adjusted difference − 15.56 percentage points; p = 0.029), whereas other knee kinematic outcomes did not differ significantly between treatments. Pain intensity (BPI-5) was significantly lower following FES than non-FES (adjusted difference − 1.80 points; p < 0.001). Pain interference (BPI-9) did not differ significantly between treatments (p = 0.144), although an exploratory post-hoc subgroup analysis suggested reduced interference among participants with baseline BPI-9 ≥ 3 (p = 0.013). Phantom limb pain intensity decreased by 2.78 points following FES among participants reporting phantom limb pain at baseline (n = 9; p < 0.001). Conclusions Community-based quadriceps FES during gait was feasible and well tolerated, with high adherence. Exploratory findings suggested improvements in knee flexion symmetry and reduced pain intensity, although other kinematic measures and pain interference showed less conclusive effects. The observed reduction in phantom limb pain warrants prospective evaluation in adequately powered trials. Trial registration: ISRCTN16755878 (retrospectively registered).

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-25
DOI
https://doi.org/10.21203/rs.3.rs-11701312/v1
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Feasibility of Community-Based Gait-Synchronised Functional Electrical Stimulation in Individuals with Transtibial Amputation and Chronic Pain: A Randomised Crossover Study

Paul N. Taylor, Jin Min Kim, Poorna Ramamurthy, Ziyun Ding et al.
2 links
Research Square
Prosthetics and Rehabilitation Robotics
preprint

Feasibility of Community-Based Gait-Synchronised Functional Electrical Stimulation in Individuals with Transtibial Amputation and Chronic Pain: A Randomised Crossover Study

Paul N. Taylor, Jin Min Kim, Poorna Ramamurthy, Ziyun Ding, Christine Singleton, Qingyao Bian, Tom E Nightingale, Lloyd Czaplewski
preprint en

Abstract

Background Chronic pain and altered gait commonly co-occur after transtibial amputation. Previous musculoskeletal modelling identified the residual knee extensors as a potential target for functional electrical stimulation (FES) to improve gait mechanics. Subsequent laboratory studies have demonstrated improved gait mechanics and suggested potential benefits for pain management. However, the feasibility and effects of prolonged FES use during daily life remain unclear. Methods Fourteen individuals with unilateral transtibial amputation and chronic pain completed a randomised crossover study comprising five weeks of daily quadriceps FES synchronised to the stance phase of gait and five weeks without FES, separated by a six-week washout. The primary outcome was feasibility, including retention, adherence, device use, safety, and participant feedback. Exploratory outcomes included knee kinematics assessed using wearable inertial measurement units and OpenSim-based inverse kinematics, and pain intensity and interference assessed using the Brief Pain Inventory (BPI-5 and BPI-9). FES was switched off during gait assessments to evaluate training rather than immediate orthotic effects. Scalar outcomes were analysed using baseline- and period-adjusted linear mixed-effects models. Results Retention was 100%, mean adherence was 94%, and no serious adverse events occurred. Device use averaged 3.52 ± 2.97 hours per active day. Mean frame-wise knee flexion symmetry index was significantly lower following FES than non-FES (adjusted difference − 15.56 percentage points; p = 0.029), whereas other knee kinematic outcomes did not differ significantly between treatments. Pain intensity (BPI-5) was significantly lower following FES than non-FES (adjusted difference − 1.80 points; p < 0.001). Pain interference (BPI-9) did not differ significantly between treatments (p = 0.144), although an exploratory post-hoc subgroup analysis suggested reduced interference among participants with baseline BPI-9 ≥ 3 (p = 0.013). Phantom limb pain intensity decreased by 2.78 points following FES among participants reporting phantom limb pain at baseline (n = 9; p < 0.001). Conclusions Community-based quadriceps FES during gait was feasible and well tolerated, with high adherence. Exploratory findings suggested improvements in knee flexion symmetry and reduced pain intensity, although other kinematic measures and pain interference showed less conclusive effects. The observed reduction in phantom limb pain warrants prospective evaluation in adequately powered trials. Trial registration: ISRCTN16755878 (retrospectively registered).

Research Square
Birmingham Community Healthcare NHS Trust (GB), Information Ventures (United States) (US), E7 Ventures (United States) (US), Salisbury NHS Foundation Trust (GB), University of Birmingham (GB)
Good health and well-being
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon