Biological equivalent dose assessment of hydrogel spacer dosimetric impact in prostate cancer EBRT

Background The dosimetric impact of hydrogel spacer in prostate cancer radiation therapy for reducing rectal radiation dose and mitigating toxicity has been well documented in the literature. Purpose This study aimed to evaluate rectal dose sparing with hydrogel spacer placement in prostate cancer patients treated with External Beam Radiation Therapy (EBRT) across different fractionation schemes. Methods A retrospective analysis was conducted on 254 patients: 179 patients received a hydrogel spacer, while 75 did not. Patients underwent EBRT with one of the following regimens: conventional fractionation (81 Gy in 45 fractions), hypofractionation (70 Gy in 28 fractions), or Stereotactic Body Radiotherapy (SBRT; 40 Gy in 5 fractions). To enable comparison across these schemes, volumetric doses for rectal wall (0.1, 0.5, 1, 2, 5, and 10 cm 3) were calculated as Biological Effective Doses (BED) and subsequently converted to their Biological Equivalent Doses in 2 Gy fractions (EQD2). Results Hydrogel spacer insertion significantly improved rectal dose sparing across all evaluated fractionation schemes (p < 0.01). For conventional fractionation group with spacer insertion, average rectal wall EQD2 was reduced by 13.0% to 51.4% across volumes ranging from 0.1 to 10 cm 3. EQD2_max decreased by 7.4%, and EQD2_mean by 18.2%. In hypofractionation group, spacer placement led to rectal wall EQD2 reductions of 11.1% to 43.0% across the same volumes. EQD2_max decreased by 4.3%, and EQD2_mean by 21.5%. In SBRT, spacer insertion resulted in rectal wall EQD2 decreases of 17.7% to 40.8% for those volumes. Rectal wall EQD2_max and EQD2_mean were reduced by 6.3% and 22.5%, respectively. All reported reductions were statistically significant (p < 0.01). Conclusion Hydrogel spacer insertion consistently and significantly improved rectal dose sparing for prostate cancer patients undergoing EBRT across all investigated fractionation schemes. Notably, more substantial dose reductions were observed in larger rectal wall volumes, indicating a greater protective benefit with increased tissue involvement.

Authors

Institutions

Publication Details

Journal
Journal of Applied Clinical Medical Physics
Published
2026-11-24
DOI
https://doi.org/10.1002/acm2.70868
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Biological equivalent dose assessment of hydrogel spacer dosimetric impact in prostate cancer EBRT

Jenghwa Chang, Yijian Cao, Jeffrey Antone, Louis Potters et al.
Journal of Applied Clinical Medical Physics
Advanced Radiotherapy Techniques
article

Biological equivalent dose assessment of hydrogel spacer dosimetric impact in prostate cancer EBRT

Jenghwa Chang, Yijian Cao, Jeffrey Antone, Louis Potters, Honglai Zhang
article en

Abstract

Background The dosimetric impact of hydrogel spacer in prostate cancer radiation therapy for reducing rectal radiation dose and mitigating toxicity has been well documented in the literature. Purpose This study aimed to evaluate rectal dose sparing with hydrogel spacer placement in prostate cancer patients treated with External Beam Radiation Therapy (EBRT) across different fractionation schemes. Methods A retrospective analysis was conducted on 254 patients: 179 patients received a hydrogel spacer, while 75 did not. Patients underwent EBRT with one of the following regimens: conventional fractionation (81 Gy in 45 fractions), hypofractionation (70 Gy in 28 fractions), or Stereotactic Body Radiotherapy (SBRT; 40 Gy in 5 fractions). To enable comparison across these schemes, volumetric doses for rectal wall (0.1, 0.5, 1, 2, 5, and 10 cm 3) were calculated as Biological Effective Doses (BED) and subsequently converted to their Biological Equivalent Doses in 2 Gy fractions (EQD2). Results Hydrogel spacer insertion significantly improved rectal dose sparing across all evaluated fractionation schemes (p < 0.01). For conventional fractionation group with spacer insertion, average rectal wall EQD2 was reduced by 13.0% to 51.4% across volumes ranging from 0.1 to 10 cm 3. EQD2_max decreased by 7.4%, and EQD2_mean by 18.2%. In hypofractionation group, spacer placement led to rectal wall EQD2 reductions of 11.1% to 43.0% across the same volumes. EQD2_max decreased by 4.3%, and EQD2_mean by 21.5%. In SBRT, spacer insertion resulted in rectal wall EQD2 decreases of 17.7% to 40.8% for those volumes. Rectal wall EQD2_max and EQD2_mean were reduced by 6.3% and 22.5%, respectively. All reported reductions were statistically significant (p < 0.01). Conclusion Hydrogel spacer insertion consistently and significantly improved rectal dose sparing for prostate cancer patients undergoing EBRT across all investigated fractionation schemes. Notably, more substantial dose reductions were observed in larger rectal wall volumes, indicating a greater protective benefit with increased tissue involvement.

Journal of Applied Clinical Medical PhysicsVol. 27(12)
Northwell Health (US), Hofstra University (US)
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon