Evaluating the acceptability of virtual reality visual field testing in rural Virginia

OBJECTIVE: To evaluate the acceptability of virtual reality (VR)-based visual field (VF) testing using the RetinaLogik Virtual Reality Headset Perimeter (RVF100) device in rural Virginia. METHODS: We conducted a cross-sectional study at Remote Area Medical (RAM) vision clinics in medically underserved areas of rural Virginia. Participants were 99 adults (198 eyes) aged 18 years or older with a best-corrected visual acuity of 20/200 or better in both eyes. Participants completed VF testing using the RVF100. Acceptability was assessed using the System Usability Scale (SUS), supplemented by measures of willingness to retest, dizziness or discomfort, and test completion. SUS scores were summarized descriptively and analyzed using a Gaussian generalized linear model with a log-link to examine associations with prespecified covariates. RESULTS: The median SUS score was 80.00 (A- grade, 85th-89th percentile). Willingness to retest was reported by 90/99 participants (90.9%; Wilson 95% CI, 83.6%-95.1%), 75/99 felt confident using the device (75.8%; Wilson 95% CI, 66.5%-83.1%), and 16/99 reported dizziness or discomfort (16.2%; Wilson 95% CI, 10.2%-24.7%). All 99 participants completed testing (100.0%; Wilson 95% CI, 96.3%-100.0%). Median pattern standard deviation was 1.51 dB in the right eye and 1.47 dB in the left eye; median mean deviation was -0.49 dB in both eyes, and median bilateral assessment duration was 4.78 minutes. No prespecified regression predictor met α = 0.05. CONCLUSIONS: VR-based VF testing was well accepted by participants attending rural outreach clinics and was feasible within the outreach workflow. These findings are limited to patient acceptability in a relatively young cohort in which pre-existing ocular disease and visual field status were not systematically characterized. They do not establish diagnostic accuracy or clinical effectiveness, which require direct comparison with standard automated perimetry in the populations for whom perimetry is indicated.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-11-25
DOI
https://doi.org/10.1371/journal.pone.0361218
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluating the acceptability of virtual reality visual field testing in rural Virginia

Kavin Selvan, Du Cheng, Surbhi Bansal, Sarah Abouassali et al.
3 links
PLoS ONE
Glaucoma and retinal disorders
article

Evaluating the acceptability of virtual reality visual field testing in rural Virginia

Kavin Selvan, Du Cheng, Surbhi Bansal, Sarah Abouassali, Roy Sabo, Mary K. Daly, Amanda Robinson, Omar Al-Dulaimi, Evan Silverstein, Michelle Lam, Victoria Wu, Brandon Rinkavage, Nancy Beinlich
article en

Abstract

OBJECTIVE: To evaluate the acceptability of virtual reality (VR)-based visual field (VF) testing using the RetinaLogik Virtual Reality Headset Perimeter (RVF100) device in rural Virginia. METHODS: We conducted a cross-sectional study at Remote Area Medical (RAM) vision clinics in medically underserved areas of rural Virginia. Participants were 99 adults (198 eyes) aged 18 years or older with a best-corrected visual acuity of 20/200 or better in both eyes. Participants completed VF testing using the RVF100. Acceptability was assessed using the System Usability Scale (SUS), supplemented by measures of willingness to retest, dizziness or discomfort, and test completion. SUS scores were summarized descriptively and analyzed using a Gaussian generalized linear model with a log-link to examine associations with prespecified covariates. RESULTS: The median SUS score was 80.00 (A- grade, 85th-89th percentile). Willingness to retest was reported by 90/99 participants (90.9%; Wilson 95% CI, 83.6%-95.1%), 75/99 felt confident using the device (75.8%; Wilson 95% CI, 66.5%-83.1%), and 16/99 reported dizziness or discomfort (16.2%; Wilson 95% CI, 10.2%-24.7%). All 99 participants completed testing (100.0%; Wilson 95% CI, 96.3%-100.0%). Median pattern standard deviation was 1.51 dB in the right eye and 1.47 dB in the left eye; median mean deviation was -0.49 dB in both eyes, and median bilateral assessment duration was 4.78 minutes. No prespecified regression predictor met α = 0.05. CONCLUSIONS: VR-based VF testing was well accepted by participants attending rural outreach clinics and was feasible within the outreach workflow. These findings are limited to patient acceptability in a relatively young cohort in which pre-existing ocular disease and visual field status were not systematically characterized. They do not establish diagnostic accuracy or clinical effectiveness, which require direct comparison with standard automated perimetry in the populations for whom perimetry is indicated.

PLoS ONEVol. 21(11)
Virginia Commonwealth University (US)
National Institutes of Health, National Center for Advancing Translational Sciences
Good health and well-being
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon