Design and Experimental Validation of an APSO-Optimized Fractional-Order PI Controller for a Single-Phase Boost Power Factor Correction Converter

This paper presents the design and implementation of an Adaptive Particle Swarm Optimization (APSO)-optimized Fractional-Order Proportional-Integral (FOPI) controller for a single-phase AC–DC boost Power Factor Correction (PFC) converter. The optimization employs an Integral of Time-weighted Absolute Error (ITAE)-centered composite objective function incorporating Integral Absolute Error (IAE), overshoot, settling time, control effort, and control-signal variation. The inertia weight, cognitive coefficient, and social coefficient are adaptively varied throughout the optimization process to promote a progressive transition from global exploration to local exploitation. The fractional-order integrator is approximated using the Oustaloup method, and the resulting rational transfer function is subsequently discretized using the Tustin (bilinear) transformation for digital implementation. The proposed controller is evaluated in MATLAB/Simulink under steady-state and transient operating conditions and is subsequently implemented experimentally using a dSPACE 1104 real-time control system. The experimental results demonstrate a near-unity Power Factor (PF) of 0.997 and an input-current Total Harmonic Distortion (THD) of 4.3% under steady-state operation. For DC-link voltage reference variations, the FOPI controller achieves a settling time of approximately 50 ms in simulation and 60 ms experimentally. Under load-resistance variations, the experimental DC-link voltage deviation is limited to approximately 2 V, with recovery times of about 60 ms for the tested transitions. The results demonstrate that the APSO-optimized FOPI controller provides improved dynamic DC-link voltage regulation while maintaining satisfactory steady-state power-quality performance.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-25
DOI
https://doi.org/10.21203/rs.3.rs-11691907/v1
Primary Topic
Advanced DC-DC Converters
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Design and Experimental Validation of an APSO-Optimized Fractional-Order PI Controller for a Single-Phase Boost Power Factor Correction Converter

Yassine Bensafia, Salah Amroune, Adel Ballouti, Nouri Belhaouchet et al.
1 links
Research Square
Advanced DC-DC Converters
preprint

Design and Experimental Validation of an APSO-Optimized Fractional-Order PI Controller for a Single-Phase Boost Power Factor Correction Converter

Yassine Bensafia, Salah Amroune, Adel Ballouti, Nouri Belhaouchet, Eustache Hakizimana
preprint en

Abstract

This paper presents the design and implementation of an Adaptive Particle Swarm Optimization (APSO)-optimized Fractional-Order Proportional-Integral (FOPI) controller for a single-phase AC–DC boost Power Factor Correction (PFC) converter. The optimization employs an Integral of Time-weighted Absolute Error (ITAE)-centered composite objective function incorporating Integral Absolute Error (IAE), overshoot, settling time, control effort, and control-signal variation. The inertia weight, cognitive coefficient, and social coefficient are adaptively varied throughout the optimization process to promote a progressive transition from global exploration to local exploitation. The fractional-order integrator is approximated using the Oustaloup method, and the resulting rational transfer function is subsequently discretized using the Tustin (bilinear) transformation for digital implementation. The proposed controller is evaluated in MATLAB/Simulink under steady-state and transient operating conditions and is subsequently implemented experimentally using a dSPACE 1104 real-time control system. The experimental results demonstrate a near-unity Power Factor (PF) of 0.997 and an input-current Total Harmonic Distortion (THD) of 4.3% under steady-state operation. For DC-link voltage reference variations, the FOPI controller achieves a settling time of approximately 50 ms in simulation and 60 ms experimentally. Under load-resistance variations, the experimental DC-link voltage deviation is limited to approximately 2 V, with recovery times of about 60 ms for the tested transitions. The results demonstrate that the APSO-optimized FOPI controller provides improved dynamic DC-link voltage regulation while maintaining satisfactory steady-state power-quality performance.

Research Square
University of Bouira (DZ), University Ferhat Abbas of Setif (DZ), University of Rwanda (RW), University Mohamed Boudiaf of M'sila (DZ)
Industry, innovation and infrastructure, Affordable and clean energy
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.