A deep learning-based motion blur removal and super-resolution method for online longitudinal strain measurement in flexible roll forming

Flexible roll forming (FRF) involves complex interactions between transverse bending and redundant longitudinal strain, which can lead to defects such as web warping and edge flare. Accurate online measurement of strain evolution is critical for real-time control of the deformation process. However, measuring longitudinal strain at high speed remains challenging due to limitations of traditional strain gauges and digital image correlation (DIC), such as speckle degradation and motion blur. This study proposes a non-contact method combining a compact monocular stereo imaging system with a deep learning-based image processing framework. The primary contribution of this paper lies in the system-level integration of a compact monocular stereo imaging device—specifically designed to overcome the severe spatial constraints between roll stands—with a task-optimized image enhancement pipeline (MBR/ESPCN). This integrated framework effectively resolves the coupled challenges of dynamic motion blur and marker degradation, ensuring reliable 3D reconstruction and accurate strain measurement under high-speed FRF environments. Experimental validation under quasi-static tensile and high-speed FRF conditions shows the method achieves high accuracy across different deformation scales. The mean absolute error (MAE) is 0.34% under large-strain tensile loading and remains below 0.10% under equivalent high-speed dynamic conditions up to 500 mm/s. Compared with bicubic and ESPCN models, the proposed method reduces MAE by up to 65.2% and offers the lowest maximum error across all test cases. These results demonstrate the method’s robustness and suitability for small-strain, high-speed measurements in industrial environments.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2026-11-25
DOI
https://doi.org/10.1088/1361-6501/aec6c8
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A deep learning-based motion blur removal and super-resolution method for online longitudinal strain measurement in flexible roll forming

Yong Sun, Yangna Yin, Yuxi Wu, Xinyu Hu et al.
1 links
Measurement Science and Technology
Optical measurement and interference techniques
article

A deep learning-based motion blur removal and super-resolution method for online longitudinal strain measurement in flexible roll forming

Yong Sun, Yangna Yin, Yuxi Wu, Xinyu Hu, Chaohai Liu, Chengnan Long, Junfeng Xiao, Yifan Jin, Shanlin Chen
article en

Abstract

Flexible roll forming (FRF) involves complex interactions between transverse bending and redundant longitudinal strain, which can lead to defects such as web warping and edge flare. Accurate online measurement of strain evolution is critical for real-time control of the deformation process. However, measuring longitudinal strain at high speed remains challenging due to limitations of traditional strain gauges and digital image correlation (DIC), such as speckle degradation and motion blur. This study proposes a non-contact method combining a compact monocular stereo imaging system with a deep learning-based image processing framework. The primary contribution of this paper lies in the system-level integration of a compact monocular stereo imaging device—specifically designed to overcome the severe spatial constraints between roll stands—with a task-optimized image enhancement pipeline (MBR/ESPCN). This integrated framework effectively resolves the coupled challenges of dynamic motion blur and marker degradation, ensuring reliable 3D reconstruction and accurate strain measurement under high-speed FRF environments. Experimental validation under quasi-static tensile and high-speed FRF conditions shows the method achieves high accuracy across different deformation scales. The mean absolute error (MAE) is 0.34% under large-strain tensile loading and remains below 0.10% under equivalent high-speed dynamic conditions up to 500 mm/s. Compared with bicubic and ESPCN models, the proposed method reduces MAE by up to 65.2% and offers the lowest maximum error across all test cases. These results demonstrate the method’s robustness and suitability for small-strain, high-speed measurements in industrial environments.

Measurement Science and Technology
University of Electronic Science and Technology of China (CN)
Basic and Applied Basic Research Foundation of Guangdong Province
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon