Multicenter prospective study comparing ultra-low-dose CT, conventional radiography, and standard-dose CT for fracture detection in traumatology

OBJECTIVES: To compare the diagnostic performance of ultra-low-dose CT (ULD-CT) and conventional radiography (CR) for fracture detection in trauma patients, using standard-dose CT (STD-CT) as the reference. MATERIALS AND METHODS: This prospective study on diagnostic accuracy was conducted at five centers from October 2019 to September 2023 and included adult participants with suspected fractures of the extremities, pelvis/hip, or thoracolumbar spine. All participants underwent CR, ULD-CT, and STD-CT during the same visit. Blinded radiologists independently assessed fractures and associated abnormalities. Sensitivity, specificity, accuracy, radiation dose, image quality, and interpretation time were evaluated. RESULTS: Five hundred and thirty-three participants (mean age, 52 ± 22 years; 283 women) were evaluated, including 282 (53%) with fractures. For fracture detection, CR yielded 201 out of 282 true positives (sensitivity: 71% [65-76%]) and 81 out of 282 false negatives (29%), compared with 269 out of 282 true positives (sensitivity: 95% [92-98%]) and 13 out of 282 false negatives (5%) with ULD-CT (p < 0.01). Specificity was 242 out of 251 (96% [93-98%]) for CR and 245 out of 251 (98% [95-99%]) for ULD-CT (p = 0.58). ULD-CT showed higher sensitivity for both articular (154 of 171 (90%) vs. 93 of 171 (54%); p < 0.001) and soft-tissue abnormalities related to trauma (287 of 315 (91%) vs. 184 of 315 (58%); p < 0.001). Effective dose (E) was lower with ULD-CT than with STD-CT (p < 0.01) but higher than with CR, except for distal extremities (p = 0.33). CONCLUSION: ULD-CT demonstrated higher sensitivity than CR for fracture detection, with similar specificity, using standard-dose CT as the reference. KEY POINTS: Question Can ultra-low-dose CT (ULD-CT) improve detection of fractures and associated traumatic abnormalities compared with conventional radiography (CR) while maintaining high diagnostic confidence? Findings ULD-CT showed significantly higher sensitivity than CR for fractures, articular injuries, and soft-tissue abnormalities, with similar specificity. Clinical relevance ULD-CT increased diagnostic confidence and improved detection of fractures and associated traumatic abnormalities compared with CR, potentially reducing missed injuries and the need for additional imaging examinations despite slightly longer interpretation times.

Authors

Institutions

Publication Details

Journal
European Radiology
Published
2026-11-25
DOI
https://doi.org/10.1007/s00330-026-13061-x
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Multicenter prospective study comparing ultra-low-dose CT, conventional radiography, and standard-dose CT for fracture detection in traumatology

Djamel Dabli, Jean-Paul Bérégi, Patrick Omoumi, Maxime Pastor et al.
2 links
European Radiology
Radiation Dose and Imaging
article

Multicenter prospective study comparing ultra-low-dose CT, conventional radiography, and standard-dose CT for fracture detection in traumatology

Djamel Dabli, Jean-Paul Bérégi, Patrick Omoumi, Maxime Pastor, Chris Serrand, Joël Greffier, Wissem Nabi, Oumaya Ben Said
article en

Abstract

OBJECTIVES: To compare the diagnostic performance of ultra-low-dose CT (ULD-CT) and conventional radiography (CR) for fracture detection in trauma patients, using standard-dose CT (STD-CT) as the reference. MATERIALS AND METHODS: This prospective study on diagnostic accuracy was conducted at five centers from October 2019 to September 2023 and included adult participants with suspected fractures of the extremities, pelvis/hip, or thoracolumbar spine. All participants underwent CR, ULD-CT, and STD-CT during the same visit. Blinded radiologists independently assessed fractures and associated abnormalities. Sensitivity, specificity, accuracy, radiation dose, image quality, and interpretation time were evaluated. RESULTS: Five hundred and thirty-three participants (mean age, 52 ± 22 years; 283 women) were evaluated, including 282 (53%) with fractures. For fracture detection, CR yielded 201 out of 282 true positives (sensitivity: 71% [65-76%]) and 81 out of 282 false negatives (29%), compared with 269 out of 282 true positives (sensitivity: 95% [92-98%]) and 13 out of 282 false negatives (5%) with ULD-CT (p < 0.01). Specificity was 242 out of 251 (96% [93-98%]) for CR and 245 out of 251 (98% [95-99%]) for ULD-CT (p = 0.58). ULD-CT showed higher sensitivity for both articular (154 of 171 (90%) vs. 93 of 171 (54%); p < 0.001) and soft-tissue abnormalities related to trauma (287 of 315 (91%) vs. 184 of 315 (58%); p < 0.001). Effective dose (E) was lower with ULD-CT than with STD-CT (p < 0.01) but higher than with CR, except for distal extremities (p = 0.33). CONCLUSION: ULD-CT demonstrated higher sensitivity than CR for fracture detection, with similar specificity, using standard-dose CT as the reference. KEY POINTS: Question Can ultra-low-dose CT (ULD-CT) improve detection of fractures and associated traumatic abnormalities compared with conventional radiography (CR) while maintaining high diagnostic confidence? Findings ULD-CT showed significantly higher sensitivity than CR for fractures, articular injuries, and soft-tissue abnormalities, with similar specificity. Clinical relevance ULD-CT increased diagnostic confidence and improved detection of fractures and associated traumatic abnormalities compared with CR, potentially reducing missed injuries and the need for additional imaging examinations despite slightly longer interpretation times.

European Radiology
Université de Montpellier (FR), Centre Hospitalier Universitaire Vaudois (CH), Centre Hospitalier Universitaire de Nîmes (FR), Initial MAnagement and prevention of acute orGan failures IN critically ill patiEnts (FR), Université de Nîmes (FR), University of Lausanne (CH)
Agence Nationale de la Recherche
Good health and well-being
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon