Transient current technique characterization of ultra-thin neutron-irradiated 4H-SiC radiation detectors

Silicon carbide is a promising material for radiation-hard detectors operating under high beam-rate conditions, such as those required in the emerging FLASH radiotherapy. However, different radiation qualities can introduce defects that degrade the detector response and lifetime. This work aims to assess the radiation hardness of 4H-SiC planar detectors by evaluating their response after neutron irradiation using the transient current technique (TCT). 4H-SiC p-n junction detectors with a diameter of 2200 \(\mu\) m and a thickness of 3 \(\mu\) m were characterized to evaluate their response after 1 MeV neutron equivalent fluence irradiation of 8 \(\times\) 10 \(^{14}\) cm \(^{-2}\) (TRIGA Mark II reactor, Ljubljana, Slovenia). Electrical performance was studied by measuring the I-V and C-V characteristics pre- and post-irradiation. Spatial uniformity and charge collection degradation were investigated using the TCT, with a 370 nm UV laser at repetition rates of 1 kHz and 41 MHz. TCAD simulations were additionally employed to compare with the experimental charge collection results. Under reverse bias, irradiation induces leakage currents on the order of a few pA and a reduction in capacitance, accompanied by a slight flattening of the C–V characteristics, consistent with a partial compensation of the epitaxial layer. At zero bias, measurements at 1 kHz and 41 MHz yield consistent average reductions in collected charge of 58 ± 10 % and 58 ± 1 %, respectively, between non-irradiated and irradiated detectors. For a fluence of 8 \(\times\) 10 \(^{14}\) n \(_{eq}\) /cm \(^{2}\) , the charge collection efficiency is 39.9 ± 0.8 %, 57.6 ± 1.2 % and 62.1 ± 1.3 % for 0 V, 5 V and 10 V, respectively. The TCAD model reproduces the collected charge with good accuracy (within 6.5 %), except at 0 V for the irradiated detector, where a discrepancy of 35.6 ± 0.2 % is observed, likely due to diffusion-dominated transport and unaccounted interface and defect-related effects​. The 4H-SiC p-n junction detectors maintain low leakage current in the range of a few pA after irradiation at 8 \(\times\) 10 \(^{14}\) n \(_{eq}\) /cm \(^{2}\) , enabling stable room temperature operation. Both UV-TCT setups yield consistent trends in detector response, with reduced variability at higher laser repetition rates due to improved signal-to-noise ratio. The measurements further confirm that charge collection degradation can be partially mitigated by increasing the applied reverse bias. Comparison with TCAD software indicates a clear loss of sensitivity of the neutron irradiated detector, however, further optimization of the defect and interface models is still required to better reproduce the neutron damage in the thin 4H-SiC detector, particularly under diffusion-dominated transport conditions. Despite a sensitivity reduction of approximately 58 % at the investigated fluence, the detectors remain operational, highlighting their suitability for long-term application.

Authors

Institutions

Publication Details

Journal
Discover Applied Sciences
Published
2026-11-25
DOI
https://doi.org/10.1007/s42452-026-09806-4
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Transient current technique characterization of ultra-thin neutron-irradiated 4H-SiC radiation detectors

Celeste Maria Fleta, Ivan Lopez Paz, Consuelo Guardiola, Marcio Jiménez Venegas
1 links
Discover Applied Sciences
Particle Detector Development and Performance
article

Transient current technique characterization of ultra-thin neutron-irradiated 4H-SiC radiation detectors

Celeste Maria Fleta, Ivan Lopez Paz, Consuelo Guardiola, Marcio Jiménez Venegas
article en

Abstract

Silicon carbide is a promising material for radiation-hard detectors operating under high beam-rate conditions, such as those required in the emerging FLASH radiotherapy. However, different radiation qualities can introduce defects that degrade the detector response and lifetime. This work aims to assess the radiation hardness of 4H-SiC planar detectors by evaluating their response after neutron irradiation using the transient current technique (TCT). 4H-SiC p-n junction detectors with a diameter of 2200 \(\mu\) m and a thickness of 3 \(\mu\) m were characterized to evaluate their response after 1 MeV neutron equivalent fluence irradiation of 8 \(\times\) 10 \(^{14}\) cm \(^{-2}\) (TRIGA Mark II reactor, Ljubljana, Slovenia). Electrical performance was studied by measuring the I-V and C-V characteristics pre- and post-irradiation. Spatial uniformity and charge collection degradation were investigated using the TCT, with a 370 nm UV laser at repetition rates of 1 kHz and 41 MHz. TCAD simulations were additionally employed to compare with the experimental charge collection results. Under reverse bias, irradiation induces leakage currents on the order of a few pA and a reduction in capacitance, accompanied by a slight flattening of the C–V characteristics, consistent with a partial compensation of the epitaxial layer. At zero bias, measurements at 1 kHz and 41 MHz yield consistent average reductions in collected charge of 58 ± 10 % and 58 ± 1 %, respectively, between non-irradiated and irradiated detectors. For a fluence of 8 \(\times\) 10 \(^{14}\) n \(_{eq}\) /cm \(^{2}\) , the charge collection efficiency is 39.9 ± 0.8 %, 57.6 ± 1.2 % and 62.1 ± 1.3 % for 0 V, 5 V and 10 V, respectively. The TCAD model reproduces the collected charge with good accuracy (within 6.5 %), except at 0 V for the irradiated detector, where a discrepancy of 35.6 ± 0.2 % is observed, likely due to diffusion-dominated transport and unaccounted interface and defect-related effects​. The 4H-SiC p-n junction detectors maintain low leakage current in the range of a few pA after irradiation at 8 \(\times\) 10 \(^{14}\) n \(_{eq}\) /cm \(^{2}\) , enabling stable room temperature operation. Both UV-TCT setups yield consistent trends in detector response, with reduced variability at higher laser repetition rates due to improved signal-to-noise ratio. The measurements further confirm that charge collection degradation can be partially mitigated by increasing the applied reverse bias. Comparison with TCAD software indicates a clear loss of sensitivity of the neutron irradiated detector, however, further optimization of the defect and interface models is still required to better reproduce the neutron damage in the thin 4H-SiC detector, particularly under diffusion-dominated transport conditions. Despite a sensitivity reduction of approximately 58 % at the investigated fluence, the detectors remain operational, highlighting their suitability for long-term application.

Discover Applied Sciences
Centro Nacional de Microelectrónica (ES), Institut de Microelectrònica de Barcelona (ES)
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon