3D Reconstruction of the Infant Hip Joint from 2D Ultrasound Sweep Sequences for DDH

Infant hip ultrasound screening is crucial for the diagnosis of developmental dysplasia of the hip (DDH). However, accurately understanding the complex hip joint anatomy and identifying the Graf standard plane from two-dimensional (2D) ultrasound images alone remains challenging. Therefore, this study developed and evaluated a three-dimensional (3D) visualization method for reconstructing infant hip structures from 2D ultrasound sweep sequences. In this method, a six-degree-of-freedom robotic arm equipped with a 2D linear-array ultrasound probe was used to perform linear scanning of an infant hip ultrasound phantom, synchronously acquiring ultrasound images and the end-effector poses of the robotic arm at 0.2 mm intervals. By fully exploiting information from adjacent frames, BCAS-UNet++, which integrates atrous spatial pyramid pooling and bidirectional convolutional long short-term memory networks, was employed to segment the hip structures. Finally, continuous 3D visualization of the infant hip joint was achieved using an improved MB-Marching Cubes reconstruction algorithm. Experiments based on the phantom dataset yielded an average surface distance of 0.8717 mm, a Hausdorff distance of 2.3713 mm, a Dice coefficient of 0.8536, and an IoU of 0.7446, while the relative errors of the α angle and β angle were 1.04% and 2.83%, respectively. In the preliminary clinical evaluation involving five infants, the mean absolute errors of the α and β angles were 1.14 ± 0.42° and 2.02 ± 0.84°, respectively, with corresponding mean relative errors of 1.70% and 3.23%. Moreover, for the α angle, the 95% limits of agreement ranged from −2.83° to 2.28°, with the systematic bias being close to zero. In conclusion, the proposed method shows promising potential to assist infant DDH screening through 3D visualization and Graf-angle assessment, although further large-scale clinical validation is needed.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-11-24
DOI
https://doi.org/10.3390/bioengineering13121433
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

3D Reconstruction of the Infant Hip Joint from 2D Ultrasound Sweep Sequences for DDH

Yuxiang Dai, Wenyi Zhang, Jianwei Cui, Jiakuan Wang
Bioengineering
Medical Image Segmentation Techniques
article

3D Reconstruction of the Infant Hip Joint from 2D Ultrasound Sweep Sequences for DDH

Yuxiang Dai, Wenyi Zhang, Jianwei Cui, Jiakuan Wang
article en

Abstract

Infant hip ultrasound screening is crucial for the diagnosis of developmental dysplasia of the hip (DDH). However, accurately understanding the complex hip joint anatomy and identifying the Graf standard plane from two-dimensional (2D) ultrasound images alone remains challenging. Therefore, this study developed and evaluated a three-dimensional (3D) visualization method for reconstructing infant hip structures from 2D ultrasound sweep sequences. In this method, a six-degree-of-freedom robotic arm equipped with a 2D linear-array ultrasound probe was used to perform linear scanning of an infant hip ultrasound phantom, synchronously acquiring ultrasound images and the end-effector poses of the robotic arm at 0.2 mm intervals. By fully exploiting information from adjacent frames, BCAS-UNet++, which integrates atrous spatial pyramid pooling and bidirectional convolutional long short-term memory networks, was employed to segment the hip structures. Finally, continuous 3D visualization of the infant hip joint was achieved using an improved MB-Marching Cubes reconstruction algorithm. Experiments based on the phantom dataset yielded an average surface distance of 0.8717 mm, a Hausdorff distance of 2.3713 mm, a Dice coefficient of 0.8536, and an IoU of 0.7446, while the relative errors of the α angle and β angle were 1.04% and 2.83%, respectively. In the preliminary clinical evaluation involving five infants, the mean absolute errors of the α and β angles were 1.14 ± 0.42° and 2.02 ± 0.84°, respectively, with corresponding mean relative errors of 1.70% and 3.23%. Moreover, for the α angle, the 95% limits of agreement ranged from −2.83° to 2.28°, with the systematic bias being close to zero. In conclusion, the proposed method shows promising potential to assist infant DDH screening through 3D visualization and Graf-angle assessment, although further large-scale clinical validation is needed.

BioengineeringVol. 13(12)
Southeast University (CN)
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon