Interface-Tailored Hydrogel Microneedle Array Patch with Laser-Engraved Graphene Electrodes for Continual In Vivo Interstitial Fluid Monitoring

Microneedle-based interstitial fluid (ISF) analysis has advanced rapidly for wearable healthcare monitoring, yet the hydrogel−electrode junction connecting microneedles to electrochemical transducers remains poorly characterized. Herein, a fully flexible electrochemical patch for dual-biomarker (glucose/Na+) monitoring in ISF is reported. The patch integrates a methacrylated hyaluronic acid hydrogel microneedle array patch (HMAP) with a laser-engraved graphene (LEG) multichannel electrochemical sensor through a MeHA hydrogel interlayer. Glucose is transduced amperometrically at −0.1 V versus Ag/AgCl using a Prussian blue/nickel hexacyanoferrate-mediated glucose oxidase interface. Na+ is transduced potentiometrically using a solid-contact ion-selective electrode incorporating poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) as the ion-to-electron transducer. The interlayer concentration and dispensed volume are optimized based on the apparent interfacial resistance measured after HMAP integration. The selected interlayer formulation exhibited an apparent interfacial resistance of 17.2 Ω, approximately 3.8-fold lower than that of the highest-resistance formulation tested (65.5 Ω). Geometrically normalized amperometric sensitivity is also preserved after HMAP integration. In normoglycemic and streptozotocin-induced diabetic rats (n = 3 per model), the glucose mean absolute relative differences (MARDs) were 18.8% and 33.1%, with mean biases (patch−reference) of +0.81 and +1.90 mM, respectively. Corresponding Na+ MARDs were 3.5% and 2.8%, with mean biases of +0.79 and −3.67 mM. Diabetic glucose estimates relied on out-of-range baseline anchoring, exceeded references by 36−60% at 150−180 min, and were interpreted descriptively. These findings highlight hydrogel−electrode interface optimization as a strategy for improving microneedle-based electrochemical sensing and support further development of the HMAP−LEG patch for wearable biosensing.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-11-25
DOI
https://doi.org/10.1021/acs.analchem.6c05095
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Interface-Tailored Hydrogel Microneedle Array Patch with Laser-Engraved Graphene Electrodes for Continual In Vivo Interstitial Fluid Monitoring

Yuanting Xie, Lei Su, Xueji Zhang, Hao Li et al.
Analytical Chemistry
Electrochemical sensors and biosensors
article

Interface-Tailored Hydrogel Microneedle Array Patch with Laser-Engraved Graphene Electrodes for Continual In Vivo Interstitial Fluid Monitoring

Yuanting Xie, Lei Su, Xueji Zhang, Hao Li, Ziyu Yin, Yelan Xiao, Xinghui Li
article en

Abstract

Microneedle-based interstitial fluid (ISF) analysis has advanced rapidly for wearable healthcare monitoring, yet the hydrogel−electrode junction connecting microneedles to electrochemical transducers remains poorly characterized. Herein, a fully flexible electrochemical patch for dual-biomarker (glucose/Na+) monitoring in ISF is reported. The patch integrates a methacrylated hyaluronic acid hydrogel microneedle array patch (HMAP) with a laser-engraved graphene (LEG) multichannel electrochemical sensor through a MeHA hydrogel interlayer. Glucose is transduced amperometrically at −0.1 V versus Ag/AgCl using a Prussian blue/nickel hexacyanoferrate-mediated glucose oxidase interface. Na+ is transduced potentiometrically using a solid-contact ion-selective electrode incorporating poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) as the ion-to-electron transducer. The interlayer concentration and dispensed volume are optimized based on the apparent interfacial resistance measured after HMAP integration. The selected interlayer formulation exhibited an apparent interfacial resistance of 17.2 Ω, approximately 3.8-fold lower than that of the highest-resistance formulation tested (65.5 Ω). Geometrically normalized amperometric sensitivity is also preserved after HMAP integration. In normoglycemic and streptozotocin-induced diabetic rats (n = 3 per model), the glucose mean absolute relative differences (MARDs) were 18.8% and 33.1%, with mean biases (patch−reference) of +0.81 and +1.90 mM, respectively. Corresponding Na+ MARDs were 3.5% and 2.8%, with mean biases of +0.79 and −3.67 mM. Diabetic glucose estimates relied on out-of-range baseline anchoring, exceeded references by 36−60% at 150−180 min, and were interpreted descriptively. These findings highlight hydrogel−electrode interface optimization as a strategy for improving microneedle-based electrochemical sensing and support further development of the HMAP−LEG patch for wearable biosensing.

Analytical Chemistry
Shenzhen University (CN)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon