Optical gas thermometry with parts-per-million accuracy

Optical gas thermometry provides a quantum-based route for primary thermodynamic temperature measurement. This work reports advances in Doppler broadening thermometry (DBT) and line-intensity ratio thermometry (LRT) achieved by implementing cavity mode dispersion spectroscopy (CMDS). The CMDS technique, which relies solely on frequency measurements of cavity-mode dispersive shifts induced by molecular absorption, effectively circumvents the limitations of traditional absorption spectroscopy, such as detector nonlinearity and long-term intensity drifts. We demonstrate record-setting accuracies, with combined standard uncertainties of approximately 12 ppm for DBT and 7 ppm for LRT, establishing the most precise optical thermometry measurements achieved to date. These results validate DBT and LRT as robust, primary thermometry methods grounded in fundamental molecular physics and open new avenues for quantum metrology and precision spectroscopy.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2026-11-25
DOI
https://doi.org/10.1088/1361-6501/aec6c1
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Optical gas thermometry with parts-per-million accuracy

Shui-Ming Hu, Yan Tan, Qi Huang, Jin Wang et al.
Measurement Science and Technology
Calibration and Measurement Techniques
article

Optical gas thermometry with parts-per-million accuracy

Shui-Ming Hu, Yan Tan, Qi Huang, Jin Wang, An-Wen Liu, Cun-Feng Cheng, Jin-Ke Li
article en

Abstract

Optical gas thermometry provides a quantum-based route for primary thermodynamic temperature measurement. This work reports advances in Doppler broadening thermometry (DBT) and line-intensity ratio thermometry (LRT) achieved by implementing cavity mode dispersion spectroscopy (CMDS). The CMDS technique, which relies solely on frequency measurements of cavity-mode dispersive shifts induced by molecular absorption, effectively circumvents the limitations of traditional absorption spectroscopy, such as detector nonlinearity and long-term intensity drifts. We demonstrate record-setting accuracies, with combined standard uncertainties of approximately 12 ppm for DBT and 7 ppm for LRT, establishing the most precise optical thermometry measurements achieved to date. These results validate DBT and LRT as robust, primary thermometry methods grounded in fundamental molecular physics and open new avenues for quantum metrology and precision spectroscopy.

Measurement Science and Technology
University of Science and Technology of China (CN)
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon