PMRIPrep: automated preprocessing and quantification of DSC and DCE MRI

While dynamic susceptibility contrast (DSC) MRI measures hemodynamics and dynamic contrast-enhanced (DCE) MRI characterizes vascular permeability, quantitative values from both modalities remain processing-dependent. We present PMRIPrep, a Brain Imaging Data Structure (BIDS) App for automated DSC and DCE preprocessing and quantification. PMRIPrep adapts to available acquisitions and metadata, integrates both modalities within a session, and supports four DSC deconvolution methods and four DCE pharmacokinetic models. In DSC simulations with 4% cerebral blood volume and signal-to-noise ratio 50, pooled median absolute cerebral blood flow error was 13-19% across methods. Median Ktrans bias remained ≤2% across four model-matched DCE configurations over 0-10% noise. End-to-end OSIPI analyses yielded DCE accuracy and clinical test-retest repeatability scores of 0.85 and 0.85, respectively. Outputs follow BIDS-Derivatives conventions and include machine-readable provenance and visual quality-control reports. PMRIPrep is freely available as a containerized application.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-25
DOI
https://doi.org/10.64898/2026.11.17.767132
Primary Topic
Advanced MRI Techniques and Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

PMRIPrep: automated preprocessing and quantification of DSC and DCE MRI

Brandon J. Curl, Sanjeev Chawla, Aaron Michael Rulseh, Suyash Mohan et al.
bioRxiv (Cold Spring Harbor Laboratory)
Advanced MRI Techniques and Applications
preprint

PMRIPrep: automated preprocessing and quantification of DSC and DCE MRI

Brandon J. Curl, Sanjeev Chawla, Aaron Michael Rulseh, Suyash Mohan, Archith Rajan, Josef Vymazal
preprint en

Abstract

While dynamic susceptibility contrast (DSC) MRI measures hemodynamics and dynamic contrast-enhanced (DCE) MRI characterizes vascular permeability, quantitative values from both modalities remain processing-dependent. We present PMRIPrep, a Brain Imaging Data Structure (BIDS) App for automated DSC and DCE preprocessing and quantification. PMRIPrep adapts to available acquisitions and metadata, integrates both modalities within a session, and supports four DSC deconvolution methods and four DCE pharmacokinetic models. In DSC simulations with 4% cerebral blood volume and signal-to-noise ratio 50, pooled median absolute cerebral blood flow error was 13-19% across methods. Median Ktrans bias remained ≤2% across four model-matched DCE configurations over 0-10% noise. End-to-end OSIPI analyses yielded DCE accuracy and clinical test-retest repeatability scores of 0.85 and 0.85, respectively. Outputs follow BIDS-Derivatives conventions and include machine-readable provenance and visual quality-control reports. PMRIPrep is freely available as a containerized application.

bioRxiv (Cold Spring Harbor Laboratory)
Fakultní nemocnice Motol a Homolka (CZ), University of Pennsylvania (US)
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon