When detection is not enough: analytical limitations of ICP-OES workflow for trace-level toxic element biomonitoring in human blood and urine

Environmental exposure to potentially toxic elements is a worldwide public health concern. Inductively coupled plasma mass spectrometry (ICP-MS) is preferred for trace-level human biomonitoring but is not universally accessible. Data were generated within a Mexican cohort using inductively coupled plasma optical emission spectrometry (ICP-OES) as a more accessible multielement alternative to measure As, Cd, Cr, Pb, and Hg in paired blood and urine from 187 participants, including patients with rheumatic diseases or osteoporosis and clinically healthy participants. Unexpected concentration patterns prompted this secondary appraisal of detectability, censoring, limits of detection (LODs), population comparators, and exploratory agreement with graphite furnace atomic absorption spectrometry (GFAAS) for blood Pb. Numerical reporting varied across elements and matrices and LODs exceeded concentrations reported in population biomonitoring, making comparator exceedance analytically inevitable. Contrasting blood–urine patterns and discordance between ICP-OES and GFAAS Pb measurements raised concerns. The evaluated workflow did not demonstrate adequate fit-for-purpose performance for trace-level biomonitoring. Nevertheless, these findings document challenges for laboratories seeking accessible alternatives to ICP-MS and highlight the need for matrix-specific validation, appropriate LODs, interference assessment, and reference-method confirmation before cohort-wide implementation.

Authors

Institutions

Publication Details

Journal
BMC Research Notes
Published
2026-11-25
DOI
https://doi.org/10.1186/s13104-026-08143-4
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

When detection is not enough: analytical limitations of ICP-OES workflow for trace-level toxic element biomonitoring in human blood and urine

Andrea Aguilar-Vázquez, Óscar Pizano-Martínez, Edy David Rubio Arellano, Mario Salazar-Páramo et al.
BMC Research Notes
Analytical chemistry methods development
article

When detection is not enough: analytical limitations of ICP-OES workflow for trace-level toxic element biomonitoring in human blood and urine

Andrea Aguilar-Vázquez, Óscar Pizano-Martínez, Edy David Rubio Arellano, Mario Salazar-Páramo, Karla Berenice Contreras-Díaz, Arcelia Llamas-García, Cynthia-Alejandra Gomez-Rios, Mónica Vázquez-Del Mercado, Christian Juarez-Gomez, Maribell Cabrera-López, Ligia Magaña-García, Jose Becerra-Jimenez, Itzel-Yoselin Arteaga-Gallegos, Mariel Vazquez-Cortes, Guillermo Toriz
article en

Abstract

Environmental exposure to potentially toxic elements is a worldwide public health concern. Inductively coupled plasma mass spectrometry (ICP-MS) is preferred for trace-level human biomonitoring but is not universally accessible. Data were generated within a Mexican cohort using inductively coupled plasma optical emission spectrometry (ICP-OES) as a more accessible multielement alternative to measure As, Cd, Cr, Pb, and Hg in paired blood and urine from 187 participants, including patients with rheumatic diseases or osteoporosis and clinically healthy participants. Unexpected concentration patterns prompted this secondary appraisal of detectability, censoring, limits of detection (LODs), population comparators, and exploratory agreement with graphite furnace atomic absorption spectrometry (GFAAS) for blood Pb. Numerical reporting varied across elements and matrices and LODs exceeded concentrations reported in population biomonitoring, making comparator exceedance analytically inevitable. Contrasting blood–urine patterns and discordance between ICP-OES and GFAAS Pb measurements raised concerns. The evaluated workflow did not demonstrate adequate fit-for-purpose performance for trace-level biomonitoring. Nevertheless, these findings document challenges for laboratories seeking accessible alternatives to ICP-MS and highlight the need for matrix-specific validation, appropriate LODs, interference assessment, and reference-method confirmation before cohort-wide implementation.

BMC Research Notes
Universidad de Guadalajara (MX), Hospital Civil de Guadalajara (MX)
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon