Research on Staged Calibration of Single Injection Mass of Marine Fuel Injectors Based on Error Separation

This study takes the system-level model of a 0.3 mm single-hole high-pressure common-rail injector as its object and, using the fuel injection quantity data from earlier experiments of the research group (injection pressure 35~140 MPa, Injection duration 700~3000 µs), proposes a staged calibration method based on error separation: first, grid independence verification of the number of high-pressure pipe nodes is completed and a parameter set is selected; 20 validation operating conditions are reserved from the samples and excluded from the fitting process, while the remaining conditions are used as optimization operating conditions for calibration; finally, the optimized model is selected for a full-map summary. After calibration, the mean absolute error over the 50 operating conditions decreases from 31.59% to 2.59%, and the maximum absolute error decreases from 57.58% to 9.54%.

Authors

Institutions

Publication Details

Journal
Frontiers in Engineering
Published
2026-11-26
DOI
https://doi.org/10.63313/fe.2012
Primary Topic
Engine and Fuel Emissions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Research on Staged Calibration of Single Injection Mass of Marine Fuel Injectors Based on Error Separation

张进良, Fengming Zhao, Guozhu Ren, Chenguang Wang et al.
Frontiers in Engineering
Engine and Fuel Emissions
article

Research on Staged Calibration of Single Injection Mass of Marine Fuel Injectors Based on Error Separation

张进良, Fengming Zhao, Guozhu Ren, Chenguang Wang, Yipeng Sang
article en

Abstract

This study takes the system-level model of a 0.3 mm single-hole high-pressure common-rail injector as its object and, using the fuel injection quantity data from earlier experiments of the research group (injection pressure 35~140 MPa, Injection duration 700~3000 µs), proposes a staged calibration method based on error separation: first, grid independence verification of the number of high-pressure pipe nodes is completed and a parameter set is selected; 20 validation operating conditions are reserved from the samples and excluded from the fitting process, while the remaining conditions are used as optimization operating conditions for calibration; finally, the optimized model is selected for a full-map summary. After calibration, the mean absolute error over the 50 operating conditions decreases from 31.59% to 2.59%, and the maximum absolute error decreases from 57.58% to 9.54%.

Frontiers in EngineeringVol. 2(2)
Tianjin University of Technology (CN)
Engine and Fuel Emissions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon