A Calibrated Gate for Evaluating Synthetic Clinical Data

Evaluation tools for synthetic patient records score fidelity (resemblance to real patients), utility (performance of models trained on the table) and privacy (exposure of real patients), combining them by arithmetic, geometric or harmonic means. Such scores are compensatory: copied training records can pass with high fidelity despite poor privacy. Under the null that a table is an unaltered sample of the source population, none of seven reviewed frameworks reports its aggregation rule's type~I error rate or power against injected flaws. We estimate both for a non-compensatory gate requiring every dimension to pass and for the arithmetic, geometric and harmonic means on identical evidence, each calibrated on the same 50 real-versus-real comparisons by a full-conformal maximum-statistic rule. For exchangeable real tables rejection on complete evidence is bounded by \(2/51\) (3.9\%) at \(\alpha = 0.05\), regardless of signal distribution. On 650 tables with injected flaws (13 flaw--dose conditions in each of 50 independent samples from a cohort of 71,518 patients), the arithmetic mean accepted 278 and the gate 170: 2.16 more flawed tables per sample (95\% interval 1.56 to 2.76; sign test \(p = 1.0 \times 10^{-8}\)). The excess held in all 21 post hoc combinations of score mapping and calibration level (interval excluding zero in 20), with mapping-dependent size; at the prespecified setting, the geometric and harmonic means did not differ detectably from the gate. The fidelity-only SDMetrics quality score accepted 579, including 47 of 50 tables entirely comprising copied training records. With fixed thresholds, the gate rejected or could not evaluate all 50 held-out real-versus-real comparisons; calibrated, it rejected 6 of 200 (3.0\%; one-sided 95\% upper bound 5.8\%). Arithmetic averaging thus admits flaws confined to one dimension; a gate attains a known type~I error rate only after calibration on real data. We did not study human reliance on these tools; code and saved results are released.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-25
DOI
https://doi.org/10.64898/2026.11.22.768435
Primary Topic
Privacy-Preserving Technologies in Data
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

A Calibrated Gate for Evaluating Synthetic Clinical Data

Syed Ahmad Chan Bukhari, Behraj Khan, Neeam Shahriar Hayder
bioRxiv (Cold Spring Harbor Laboratory)
Privacy-Preserving Technologies in Data
preprint

A Calibrated Gate for Evaluating Synthetic Clinical Data

Syed Ahmad Chan Bukhari, Behraj Khan, Neeam Shahriar Hayder
preprint en

Abstract

Evaluation tools for synthetic patient records score fidelity (resemblance to real patients), utility (performance of models trained on the table) and privacy (exposure of real patients), combining them by arithmetic, geometric or harmonic means. Such scores are compensatory: copied training records can pass with high fidelity despite poor privacy. Under the null that a table is an unaltered sample of the source population, none of seven reviewed frameworks reports its aggregation rule's type~I error rate or power against injected flaws. We estimate both for a non-compensatory gate requiring every dimension to pass and for the arithmetic, geometric and harmonic means on identical evidence, each calibrated on the same 50 real-versus-real comparisons by a full-conformal maximum-statistic rule. For exchangeable real tables rejection on complete evidence is bounded by \(2/51\) (3.9\%) at \(\alpha = 0.05\), regardless of signal distribution. On 650 tables with injected flaws (13 flaw--dose conditions in each of 50 independent samples from a cohort of 71,518 patients), the arithmetic mean accepted 278 and the gate 170: 2.16 more flawed tables per sample (95\% interval 1.56 to 2.76; sign test \(p = 1.0 \times 10^{-8}\)). The excess held in all 21 post hoc combinations of score mapping and calibration level (interval excluding zero in 20), with mapping-dependent size; at the prespecified setting, the geometric and harmonic means did not differ detectably from the gate. The fidelity-only SDMetrics quality score accepted 579, including 47 of 50 tables entirely comprising copied training records. With fixed thresholds, the gate rejected or could not evaluate all 50 held-out real-versus-real comparisons; calibrated, it rejected 6 of 200 (3.0\%; one-sided 95\% upper bound 5.8\%). Arithmetic averaging thus admits flaws confined to one dimension; a gate attains a known type~I error rate only after calibration on real data. We did not study human reliance on these tools; code and saved results are released.

bioRxiv (Cold Spring Harbor Laboratory)
St. John's University (US), St. John's University (TW)
Privacy-Preserving Technologies in Data
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon