Evaluation of direct and indirect methods for assessing passive immunity in dairy and beef-cross calves initially fed colostrum replacer: a single-farm diagnostic accuracy study

The objective of this cross-sectional diagnostic accuracy study was to evaluate the correlation between radial immunodiffusion (RID)-determined IgG and other direct and indirect measures of passive immunity in calves fed a colostrum replacer (CR). Further, we aimed to determine optimal diagnostic cutpoints for identifying failed transfer of passive immunity (FTPI; defined as serum IgG < 10 g/L) and for detecting serum IgG at concentration thresholds of 18 and 25 g/L. The study was conducted in 2024 on a 550-cow, spring-calving dairy herd in Pembrokeshire, West Wales, United Kingdom. Calves were removed from their dams when identified and received 700 g of whole bovine spray-dried colostrum containing a minimum of 100 g IgG (Calf's Choice Total 100, Saskatoon Colostrum Company Ltd., Saskatchewan, Canada) within 2 h of birth, followed by a pooled, pasteurized mix of excess dam's colostrum (not suckled by the calves) and transition milk. A total of 251 replacement heifer and beef-cross calves were blood sampled between 24 and 36 h of age. Samples were centrifuged within 1 h and serum was stored at −20 °C before analysis. Serum IgG concentrations were determined using RID and an enzyme-linked immunosorbent assay (ELISA) test (BIO-X K420, BIO-X Diagnostics, Rochefort, Belgium). Brix % and serum total protein (STP) were measured using a digital refractometer, gamma glutamyl transferase (GGT) and STP were analyzed using a wet chemistry system, and zinc sulfate turbidity (ZST) analysis was also determined for each sample. Simple linear regression models were used to evaluate correlations between RID and each test, while receiver operating characteristic (ROC) curve analysis was used to determine optimal thresholds for detecting serum IgG concentrations below 10, 18, and 25 g/L. Strong correlations were found between RID-determined IgG and STP by wet chemistry (adjusted R 2 = 0.91), ZST (adjusted R 2 = 0.89), STP measured by refractometer (adjusted R 2 = 0.83), Brix % (adjusted R 2 = 0.80), and ELISA (adjusted R 2 = 0.90). In contrast, a weaker correlation was found for GGT (adjusted R 2 = 0.18). Optimal thresholds for determining FTPI were 4.73 g/dL using STP determined by wet chemistry, 14.5 units for ZST, 5.05 g/dL for STP using a refractometer, 8.15% for Brix %, 1,312 IU/L for GGT, and 5.29 g/L for the ELISA. At the 18 and 25 g/L IgG thresholds, STP by wet chemistry, STP by refractometry, Brix %, ZST, and ELISA showed excellent discrimination, whereas GGT again showed lower diagnostic accuracy. These findings suggest that Brix %, STP, and ZST are effective indirect measures of serum IgG, with STP using wet chemistry demonstrating the strongest correlation. The ELISA performed well as a direct measure of serum IgG when compared to RID. In contrast, GGT had the lowest correlation. The choice of test for assessing passive immunity in calves fed CR should consider both the diagnostic performance and the practicality of implementation in field settings.

Authors

Institutions

Publication Details

Journal
Frontiers in Veterinary Science
Published
2026-11-25
DOI
https://doi.org/10.3389/fvets.2026.1997118
Primary Topic
Animal health and immunology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluation of direct and indirect methods for assessing passive immunity in dairy and beef-cross calves initially fed colostrum replacer: a single-farm diagnostic accuracy study

David L. Renaud, R. Davies, Alastair Macrae, Elizabeth Burrough et al.
Frontiers in Veterinary Science
Animal health and immunology
article

Evaluation of direct and indirect methods for assessing passive immunity in dairy and beef-cross calves initially fed colostrum replacer: a single-farm diagnostic accuracy study

David L. Renaud, R. Davies, Alastair Macrae, Elizabeth Burrough, Fergus Neish
article en

Abstract

The objective of this cross-sectional diagnostic accuracy study was to evaluate the correlation between radial immunodiffusion (RID)-determined IgG and other direct and indirect measures of passive immunity in calves fed a colostrum replacer (CR). Further, we aimed to determine optimal diagnostic cutpoints for identifying failed transfer of passive immunity (FTPI; defined as serum IgG < 10 g/L) and for detecting serum IgG at concentration thresholds of 18 and 25 g/L. The study was conducted in 2024 on a 550-cow, spring-calving dairy herd in Pembrokeshire, West Wales, United Kingdom. Calves were removed from their dams when identified and received 700 g of whole bovine spray-dried colostrum containing a minimum of 100 g IgG (Calf's Choice Total 100, Saskatoon Colostrum Company Ltd., Saskatchewan, Canada) within 2 h of birth, followed by a pooled, pasteurized mix of excess dam's colostrum (not suckled by the calves) and transition milk. A total of 251 replacement heifer and beef-cross calves were blood sampled between 24 and 36 h of age. Samples were centrifuged within 1 h and serum was stored at −20 °C before analysis. Serum IgG concentrations were determined using RID and an enzyme-linked immunosorbent assay (ELISA) test (BIO-X K420, BIO-X Diagnostics, Rochefort, Belgium). Brix % and serum total protein (STP) were measured using a digital refractometer, gamma glutamyl transferase (GGT) and STP were analyzed using a wet chemistry system, and zinc sulfate turbidity (ZST) analysis was also determined for each sample. Simple linear regression models were used to evaluate correlations between RID and each test, while receiver operating characteristic (ROC) curve analysis was used to determine optimal thresholds for detecting serum IgG concentrations below 10, 18, and 25 g/L. Strong correlations were found between RID-determined IgG and STP by wet chemistry (adjusted R 2 = 0.91), ZST (adjusted R 2 = 0.89), STP measured by refractometer (adjusted R 2 = 0.83), Brix % (adjusted R 2 = 0.80), and ELISA (adjusted R 2 = 0.90). In contrast, a weaker correlation was found for GGT (adjusted R 2 = 0.18). Optimal thresholds for determining FTPI were 4.73 g/dL using STP determined by wet chemistry, 14.5 units for ZST, 5.05 g/dL for STP using a refractometer, 8.15% for Brix %, 1,312 IU/L for GGT, and 5.29 g/L for the ELISA. At the 18 and 25 g/L IgG thresholds, STP by wet chemistry, STP by refractometry, Brix %, ZST, and ELISA showed excellent discrimination, whereas GGT again showed lower diagnostic accuracy. These findings suggest that Brix %, STP, and ZST are effective indirect measures of serum IgG, with STP using wet chemistry demonstrating the strongest correlation. The ELISA performed well as a direct measure of serum IgG when compared to RID. In contrast, GGT had the lowest correlation. The choice of test for assessing passive immunity in calves fed CR should consider both the diagnostic performance and the practicality of implementation in field settings.

Frontiers in Veterinary ScienceVol. 13
Roslin Institute (GB), University of Guelph (CA)
Animal health and immunology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon