Effect of Pupillary Dilation on Image Gradeability and Diagnostic Performance in AI-Based Diabetic Retinopathy Detection Among Older Adults – A Clinical Evaluation

Artificial intelligence (AI) has demonstrated significant potential in detecting diabetic retinopathy (DR) from retinal images. However, image acquisition in older adults is often affected by constricted pupils and media opacity. This study evaluated the effect of pupillary dilation on retinal image gradeability and diagnostic yield in AI-assisted DR detection among older adults. In this prospective study, adults aged ≥65 years were recruited from a tertiary eye hospital in India. Retinal images were captured using a clinically validated AI-integrated fundus camera (Optain Resolve OPTFC01, Optain Health, Melbourne, Australia) before and after pupillary dilation. The proportion of ungradable images, need for repeated imaging, and diagnostic yield of AI-based DR detection were compared between the two conditions. A total of 197 retinal images from 100 participants (mean (SD) age: 70 (4.78) years) were analysed. Ungradable images significantly decreased from 33% without dilation to 10% after dilation (p < 0.0001). The proportion requiring repeated imaging reduced from 70.6% to 33.5% (p < 0.0001). Before dilation, AI-based DR detection showed a sensitivity of 87.0% (95% CI: 73.7–95.1), a specificity of 88.7% (95% CI: 77.0–95.7), and an AUC of 0.878 (95% CI: 0.813–0.944). Corresponding values after dilation were 86.7%, 86.1%, and 0.864, respectively (p = 0.729). Our findings indicate that pupillary dilation significantly improved retinal image gradeability and reduced repeated imaging in older adults. Although diagnostic accuracy metrics remained stable, the higher proportion of gradable images enabled more patients to benefit from AI-assisted DR detection. Selective dilation may therefore be useful when non-mydriatic imaging yields ungradable results, particularly in elderly populations.

Authors

Publication Details

Journal
Figshare
Published
2026-11-25
DOI
https://doi.org/10.6084/m9.figshare.35117127
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Effect of Pupillary Dilation on Image Gradeability and Diagnostic Performance in AI-Based Diabetic Retinopathy Detection Among Older Adults – A Clinical Evaluation

Sanil Joseph, Kim Ramasamy, Thulasiraj Ravilla, Xianwen Shang et al.
Figshare
Retinal Imaging and Analysis
article

Effect of Pupillary Dilation on Image Gradeability and Diagnostic Performance in AI-Based Diabetic Retinopathy Detection Among Older Adults – A Clinical Evaluation

Sanil Joseph, Kim Ramasamy, Thulasiraj Ravilla, Xianwen Shang, Yueye Wang, Zhuoting Zhu, Jerrome Selvaraj, Mingguang He, Balagiri Sunder
article en

Abstract

Artificial intelligence (AI) has demonstrated significant potential in detecting diabetic retinopathy (DR) from retinal images. However, image acquisition in older adults is often affected by constricted pupils and media opacity. This study evaluated the effect of pupillary dilation on retinal image gradeability and diagnostic yield in AI-assisted DR detection among older adults. In this prospective study, adults aged ≥65 years were recruited from a tertiary eye hospital in India. Retinal images were captured using a clinically validated AI-integrated fundus camera (Optain Resolve OPTFC01, Optain Health, Melbourne, Australia) before and after pupillary dilation. The proportion of ungradable images, need for repeated imaging, and diagnostic yield of AI-based DR detection were compared between the two conditions. A total of 197 retinal images from 100 participants (mean (SD) age: 70 (4.78) years) were analysed. Ungradable images significantly decreased from 33% without dilation to 10% after dilation (p < 0.0001). The proportion requiring repeated imaging reduced from 70.6% to 33.5% (p < 0.0001). Before dilation, AI-based DR detection showed a sensitivity of 87.0% (95% CI: 73.7–95.1), a specificity of 88.7% (95% CI: 77.0–95.7), and an AUC of 0.878 (95% CI: 0.813–0.944). Corresponding values after dilation were 86.7%, 86.1%, and 0.864, respectively (p = 0.729). Our findings indicate that pupillary dilation significantly improved retinal image gradeability and reduced repeated imaging in older adults. Although diagnostic accuracy metrics remained stable, the higher proportion of gradable images enabled more patients to benefit from AI-assisted DR detection. Selective dilation may therefore be useful when non-mydriatic imaging yields ungradable results, particularly in elderly populations.

Figshare
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon